Fig.6
S
S
S
S
S
S
S
S
S
P22
Push & close.
If steady door is manually pushed to close direction, an automatic
closure is activated. Increase this value to adjust closing corner needed for door leaf to
start automatic closing. Setting range between 2° and 15°.
Fig.3
P21
Motor thrust time during end closing.
Increase this value to adjust time during
which the motor thurst is active in the last closing phase, thus overcoming any friction
and achieving complete door closure. At value 100% time would be 1,5''.
This parameter is not applicable for the NEPTIS SMP operator
P14
P15
Motor thrust power in closing.
(active if
F17=OFF
for spring closing units). At 0%
(default value) the function is disabled. Increase this value for higher motor thrust
power during closing phase. In swing closing units, this parameter is active only when
door closure is achieved with motor thrust.
P16
Distance between leaf physical end stop and opening end-running.
Increase
this value to increase the gap between the physical end stop on the floor and the
position of the leaf with the door full open. This setting can be adjusted for about 5°.
Fig.1
Fig.2
P10
P20
Leaf closing dealy.
For double leaf application. Increase this value to adjust closing
delay between Master and Slave unit. This setting is necessary in case of overlapping
leaves. At minimum value 0% both leaves start closing at the same time.
P19
Leaf opening delay.
For double leaf application. Increase this value to adjust opening
delay between Slave and Master unit. This setting is necessary in case of overlapping
leaves. At minimum value 0% both leaves start opening at the same time.
P18
Closing stroke to release electric lock
(active if
F04=ON
). At 0% (default value) the
function is disabled. Increase this value to adjust the closing stroke power of 0,5 second
closing before opening cycle. Used to easily release the electric lock.
Opening delay at electric lock activation
(active if
F04=ON
). By 0% (default value)
the function is disabled. Increase this value to increase the delay leaf opening in respect
of the electric lock activation (4 seconds at 100%).
P17
P12
P13
P11
Slowing down distance in opening.
Slowing down distance in opening. Distance
from where the leaf start the low speed in opening. Increase this value to adjust door
leaf slowing distance.
Slowing down distance in closing.
Slowing down distance in closing. Distance from
where the leaf start the low speed in closing. Increase this value to adjust door leaf
slowing distance.
Motor thrust during end opening.
The defaul value (12%) is low in order to reduce
leaf juddering during end opening phase. This parameter value has to be increased in
case of any difficulty in the last door opening phase and thus increasing motor thrust
power.
PARAMETER
Ref. Drawing
DESCRIPTION
*'SLAVE
36
Assisted closing virtual spring
(This parameter is active only if parameter P30 is not set to 00).
Increasing this value increases the force when the door starts closing after a manual
push opening, in all those situations where the virtual spring power is not enough to
start the reclosing cycle.