DIP SWITCH SETTING ON 4SAFE ON SW PARAMETERS ON DIGITAL PROGRAMMER N-DSEL
DIP 1 = ON
Sensor installed opening side
F21 (S08) = ON
For safety sensor in opening
DIP 1 = OFF
Sensor installed closing side
F20 (S07) = ON
For safety sensor in closing
For other option and settings available on
F22 (S09) = OFF
Test level LOW
the safety sensor, see the instructions supplied
with the sensor 4SAFE ON SW.
SETTING ON THE L-NEP BOARD
Jumper J13 =
position
P
23.3) SENSOR TOPSCAN-S
WIRING CONNECTION SENSOR TOPSCAN-S
WIRING CONNECTION NEPTIS SMP OPERATOR
Wiring between the sensor and the terminal block of the PWN-T board on Neptis SMP operator
1. (-) Supply power
TERMINAL 16 (-)
2. (+) Supply power
TERMINAL 17 (+)
3. COM
TERMINAL 7 COM
4. N.O. do not connect
5. N.C. se il sensore è installato dal lato apertura
5. N.C. se il sensore è installato dal lato chiusura
TERMINAL 5 Safety sensor in opening
TERMINAL 2 Safety sensor in closing
6. TEST test input
TERMINAL 25 TEST (+)
SETTING ON TOPSCAN-S
PARAMETERS ON DIGITAL PROGRAMMER N-DSEL
For other option and settings available on
F21 (S08) = ON
For safety sensor in opening
the safety sensor, see the instructions supplied
with the sensor TOPSCA-S, In particular make sure
F20 (S07) = ON
For safety sensor in closing
to cut configuration jumper J on the sensor according to
the instructions of the TOPSCAN-S.
F22 (S09) = ON
Test level HIGH
SETTING ON THE L-NEP BOARD
Jumper J13 =
position
P
The parameter 26 on digital programmer N-DSEL adjusts the timing of testing of the safety sensor. In case of failure of safety test on
the sensor TOPSCAN-S may need to increase the value of this parameter
.
The test of the safety sensors occurs at the beginning of each cycle of opening and closing of the door.
If the sensor does not respond properly to the test the buzzer on the operator control unit will beep, and the speed of the leaf will be slow (at
safety speed) for the entire cycle.
WIRING CONNECTION SENSOR 4SAFE ON SW
WIRING CONNECTION
NEPTIS SMP OPERATOR
Wiring between the sensor and the terminal block of the PWN-T board on Neptis SMP operator
1. GREEN (+) Supply power
TERMINAL 17 (+)
2. BROWN (-) Supply power
TERMINAL 16 (-)
3. YELLOW COM (Opening side)
TERMINAL 7 COM
4. WHITE N.C. (Opening side)
TERMINAL 5 Safety sensor in opening
5. BLACK N.O. (Opening side) do not connect
6. PINK COM (Closing side)
TERMINAL 3 COM
7. VIOLET N.C. (Closing side)
TERMINAL 2 Safety sensor in closing
8. GREY N.O. (Closing side) do not connect
9. RED (+) Test input
TERMINAL 25 TEST (+)
10. BLUE (-) Test input
TERMINAL 26 GND (-)
23.2) SENSOR 4SAFE ON SW
48