LED BLINKING SLOW
full memory or transmitter already saved
LED OFF
LED ON
LED BLINKING FAS
transmitter saving
LED BLINKING VERY FAS
memory cancellation
FIG. 1
SPYC
SPYC
1
3
FIG. 3
FIG. 2
50
25)
DISABLED PEOPLE COURTESY FUNCTION
Enable this function by setting function
F12=ON
on the digital programmer N-DSEL.
Ÿ
The inputs suitable for use by disabled people must be connected to the START or OPEN input terminals.
Even the remote control SPYCO combined with radio receiver EN/RF1 can be used as disable people input.
Ÿ
on the digital programmer N-DSEL
Adjust the pause time (parameter P05
) to hold the door open for a sufficient time to allow the
disabled person to be able to pass through the door before the automatic closing.
Ÿ
If at the end of the opening cycle or during the pause time, the safety sensor in closing detects the presence of the disabled people,
the pause time is reduced to 3 seconds (even if is set at higher value) after which the door closes .
Ÿ
The door closes immediately without taking into account the pause time if the opening is activated by external radar input , internal
radar input or with a manual push if push & go function is enable.
LED MEANING
Содержание Neptis SMP
Страница 8: ...5 TECHNICAL DRAWINGS 8 ...
Страница 9: ...9 ...
Страница 10: ...10 At door open a mechanical end stop has to be installed ...
Страница 11: ...11 At door open a mechanical end stop has to be installed ...
Страница 17: ...17 8 SELECTING THE OPENING DIRECTION IN FUNCTION OF ARM ...