1 - GENERAL INFORMATION
The EN/RF1 single-channel receiver is a 433.92 MHz radio receiver designed to open the Neptis SMP automatic door using the SPYCO
transmitters manufactured by Label.
2 - USE
The EN/RF1 receiver must be coupled to the J12 connector of the L-NEP electronic control unit and it is prearranged to operate the opening
of the automatic door in all the automation work programs.
The automatic door opening control is given by the SPYCO radio-control, while the protection and safety of the door movement are ensured
by devices outside the receiver itself.
It shall never be used in any case where the output activation or deactivation may cause injuries and damage.
Class 3 receiver in compliance with the ETSI EN 300-220-1 V.2.1.1 (2006-04) standards, chapter 4.1.1.
3 - INSTALLATION OF THE RECEIVER
Couple the EN/RF1 receiver (fig. 1) to the J12 connector of the electronic control unit L-NEP (fig.2).
Proceed with saving the SPYCO radio-controls (fig.3) as follows:
a) Enter the programming mode of the SPYCO transmitters pressing and holding the SW1 button until the L1 led is steadily lit
(approx. 3 seconds).
b) Press the button of the SPYCO transmitter to be saved and the successful saving will be indicated by 5 fast flashings of the L1 led .
c) Afterwards, the L1 led will be steadily lit again and it will be possible to save another transmitter by repeating the described operation
from step b) and so on with all the transmitters to be used.
NOTE:
·
Should the button of an already saved transmitter be pressed during the programming phase, the L1 led of the receiver will blink slowly
for 5 times .
MEMORY FULL
·
A maximum of 250 transmitters can be saved on the receiver.
When the last memory cell available (ZC1) is reached, the L1 led will blink slowly for 5 times .
d)
Once the transmitter saving procedure is finished, exit the programming mode by pressing and holding the SW1 button until the L1 led
turns off ( O ).
4 - USE OF THE RADIO-CONTROL
By pressing the button of a saved SPYCO transmitter, the automatic door opens and the L1 led of the receiver will remain on until the button
of the transmitter is released.
The radio-control opens the door in all the automation work programs.
5 - CANCELLATION OF THE MEMORY OF THE RECEIVER
Should it be necessary to cancel all the saved transmitter codes from the memory of the EN/RF1 receiver, proceed as follows:
a) Extract the EN/RF1 receiver from the connector J12 of the L-NEP control unit.
b) Keep the receiver SW1 button pressed and then couple again the EN/RF1 receiver to the J12 connector of the L-NEP control unit.
c) Release the EN/RF1 receiver SW1 button only when the L1 led of the receiver starts blinking.
d) The L1 led will be blinking very fast for approx. 8 seconds, thus indicating the cancellation of the memory of the receiver.
e) When the cancellation of the memory of the EN/RF1 receiver is finished, the L1 led will turn off.
f) At this point, it is possible to save again the code of the transmitters to be used, following the procedure described in step 3 described
above.
6 - TECHNICAL SPECIFICATIONS
Power supply
12Vdc
Absorption
10mA stand-by - 50mA in operation
Outputs
OPEN COLLECTOR
Frequency
433.92 Mhz
Memory capacity
250 users
Range without obstacles
30 meters
Operating temperature
-20° / +55°
Receiver class (ETSI EN 300-220-1 Chapter 4.1.1) Class 3
7 - DECLARATIONS
Marketing, sale and use are valid without restrictions in all EU countries.
With this document Label SpA declares that the EN/RF1 receiver complies with all the essential requirements and with all other relevant
dispositions established by 1999/5/EC directive.
The conformity declaration is attached to the EN/RF1 receiver instructions.
24) EN/RF1 RADIO RECEIVER
49
Содержание Neptis SMP
Страница 8: ...5 TECHNICAL DRAWINGS 8 ...
Страница 9: ...9 ...
Страница 10: ...10 At door open a mechanical end stop has to be installed ...
Страница 11: ...11 At door open a mechanical end stop has to be installed ...
Страница 17: ...17 8 SELECTING THE OPENING DIRECTION IN FUNCTION OF ARM ...