FUNCTION STATUS
DESCRIPTION
*' SLAVE
OFF
Choosing the program selector: manual built-in selector or mechanical key switch EV-MSEL
ON
Choosing the program selector: digital selector N-DSEL
OFF
Singe leaf door (just on display; repeat initial set-up in order to change it)
ON
Double leaf door (just on display; repeat initial set-up in order to change it)
OFF
ON
Master operator in double leaf door application (just on display; repeat initial set-up in order to change it)
OFF
Electric lock deactivated
ON
Electric lock activated
OFF
Active function if
F04 = ON
. Impulsive functioning for electric lock
(see paragraph "Electric lock Application")
ON
Active function if
F04 = ON
. Permanent functioning for electric lock
(see paragraph "Electric lock Application")
OFF
Electric lock release excluded in free manual door program
ON
Electric lock activated for each door closing in free manual door program
(see paragraph "Electric lock Application")
F06
S
S
S
F01
F02
F03
F04
F05
Slave operator in double leaf door application (just on display; repeat initial set-up in order to change it)
17) FUNCTIONS AND REGULATIONS
To enter please digit the 10-digits technical password (for detailed information please check paragraph “Password management”
In this submenu the push buttons have the following scope:
Push Button F2 = entering the setting for functions F (see paragraph “Functions Setting”);
Push Button
= entering the setting for Parameters P (see paragraph “Parameters Setting”);
Push Button F1 = to run door opening;
Push Button F3 = it is used only in case of double leaf door application to set up the parameters on Master or Slave operator; letter M or S
displayed bottom right indicates which operator has been selected. Letter M will appear on display on top right position if
the automation is single leaf
Push Button
= to return to the general setting menu.
17.1)
FUNCTIONS SETTING
In this section the display describes the scope of the selected function;
push button F1 is setting the function in OFF;
push button F3 is setting the function in ON;
push button F2 allows proceeding to the following function;
push button allows returning to the previous function;
Here the explanation of each single function:
31
Содержание Neptis SMP
Страница 8: ...5 TECHNICAL DRAWINGS 8 ...
Страница 9: ...9 ...
Страница 10: ...10 At door open a mechanical end stop has to be installed ...
Страница 11: ...11 At door open a mechanical end stop has to be installed ...
Страница 17: ...17 8 SELECTING THE OPENING DIRECTION IN FUNCTION OF ARM ...