17.2)
PARAMETERS SETTING
In this section the display describes the type of selected parameter;
push button F1 decreases the setting value in percentage;
push button F3 increases the setting value in percentage;
push button allows proceeding to the following parameter;
push button F2 allows returning to the previous parameter;
Here the explanation of each single parameter.
PARAMETER
Ref. Drawing
DESCRIPTION
*'SLAVE
S
S
S
S
P03
Closing voltage at door closed.
Increase this value to keep the motor thrust active
with door close.
Wind stop function at door closed.
At 0% (default value) the function is disabled.
Increasing this value the motor is applying an opposite force to wind strength in order to
keep the door leaf closed.
P07
Fig.3
P09
P05
Fig.5
Final thrust for electric lock coupling
(active if
F04=ON
). Increase this value for a
higher leaf speed in the last closing phase so that an easier coupling to electric lock is
enabled.
P06
Fig.4
P08
Pause time,
can be regulated between 0 and 60 seconds. It is the time in which the
door remains open before closing.
Thrust power during opening.
Increase this value for higher motor thrust power
during opening (and closing if set closing by motor) cycle.
P04
P01
Closing speed.
Increase this value for a faster door closing speed.
Opening speed.
Increase this value for a faster door opening speed.
Fig.1
Fig.2
P02
S
S
S
S
Push & go.
At 0% (default value) the function is disabled. Distance from where a door
pushed by hand start to open automatically. Setting range between 2° and 15°.
35
Safety sensor, slow motion area in opening.
When the door leaf at the end of the opening is close to the wall, the safety sensor in
opening can detect it and stop the door. To prevent an uncomplete opening cycle the
door can moving at low speed when the sensor detect the wall. The area from where the
door reacts with a low speed instead of stop depend from this potentiometer. If P03=0
the door stop ever, increasing the value the door use low speed to approach the end of
the opening. At maximum value the area start from about 45° from the end of opening.