Door opening command
Press F1 button to open the door, but only in bi-directional and single-direction programs (if
F33 function OFF).
Press F1 button to open the door in all operating programs, both automatic and night lock (if
F33 function ON).
It is only used in one MASTER / SLAVE double-leaf door automated device
F3 button has no function on the main work program selection screen, it is only used to
switch from MASTER to SLAVE and to check that communication between operators and
N-DSEL programmer is working properly.
Letter M is displayed on top right side when Master operator is selected, letter S appears
when Slave operator is selected.
If the system is working properly, door working program is displayed both with M and S, in
case of fail communication the message "NO COMUNICATION" is displayed for the non-
working-properly operator.
Operation of other buttons located on N-DSEL program selector panel
Pedestrian opening, used in double-leaf door automated device only
To activate pedestrian opening, press the button.
the symbol on the display indicates that the function is on.
In a double leaf door, the first leaf (Master) only opens if the opening command is given by
internal or external radar inputs.
The pedestrian opening only operates in bi-directional, single-direction and open door
automatic programs.
To deactivate pedestrian opening, press again the button.
For more information, refer to "Pedestrian opening" paragraph.
Deactivation of step-by-step operation
Give a pulse to F2 button to deactivate the step-by-step operation previously activated by
F13 function ON (see para. “Functions setting”) and enable the door automatic closing.
Press F2 button again to activate step-by-step operation. Symbol F2 on display goes off.
F2
F1
F3
29
SCHEDULED MAINTENANCE
If the display shows the message "
SCHEDULED MAINTENANCE
", contact the authorized service
center to request maintenance on the system.