Choose whether you want to store, or not, the opening control on the radar in a door when the other door still in movement.
F28 = OFF
: disable storage opening command.
To open a door is necessary to activate again the radar when the other door is closed.
F28 = ON
: enable storage opening command.
To open one of the two doors can activate the radar even when the other door still moving;
the opening will be automatically executed as soon as the door in moving stop in closed position.
·
It's possible to override the interlock function (one of the door open even if the other door has not yet closed) in case one door have it's
sensors activated for a time set by parameter P27. The interlock function come back to normal when the door arrived to fully close.
P27 = 0%
:
function is disabled and second door opening only after first closed.
P27 = 01%
: second door opening after 10 seconds from first door open, if its radar is continuously detect.
P27 = 100%
: second door opening after 2 minutes from first door open, if its radar continuously detect.
Steps of interlock operation are the following:
a.) person comes from outside activates the radar of the door 1 and the door 1 is opened;
b.) person enter inside area between two doors;
c.) door 1 closes after pause time;
d.) person must activate internal radar of second door to obtain second door opening;
e.) door 2 opening after door 1 closed;
f.) person enter from door 2, and this closes at the end of pause time.
The operation is the same coming from the opposite direction.
To open the door even when the other is open, it is necessary to operate the command of OPEN input.
27.3) INTERLOCK APPLICATION WITH ONLY ONE INTERNAL RADAR
It's possible to use a single sensor that cover the common inside area to open the door. Connected the sensor in parallel at Start input in both
modules PWN-T of each operator, may be necessary when distance between two doors does not allow use of two independent radar.
·
Set the function
F26 =ON
on both operators.
·
Select which of the two ports must be opened first in the event of simultaneous control of both:
F27 = OFF
:
opening with 0,5 seconds of delay after command.
F27 = ON
:
opening immediately after command.
Determine which of the two ports to be preferred to open immediately and set the function
F27 = ON, on the other set F27 = OFF.
Steps of interlock operation are the following:
a.) person comes from outside activates the radar of the door 1 and the door 1 is opened;
b.) person enter inside area between two doors and detected by common sensor;
c.) door 1 closes after pause time (detection is disabled on Start input of door 1 during pause time, during closing cycle and during 5
seconds after end closing).
d.) door 2 opening after door 1 closed if internal common radar is active on Start input;
e.) person enter from door 2, and this closes at the end of pause time.
The operation is the same coming from the opposite direction.
To open the door even when the other is open, it is necessary to operate the command of OPEN input.
EXTERNAL
RADAR
INTERNAL
RADAR
DOOR 1
DOOR 2
START
COMMON DETECTOR
57
Содержание Neptis SMP
Страница 8: ...5 TECHNICAL DRAWINGS 8 ...
Страница 9: ...9 ...
Страница 10: ...10 At door open a mechanical end stop has to be installed ...
Страница 11: ...11 At door open a mechanical end stop has to be installed ...
Страница 17: ...17 8 SELECTING THE OPENING DIRECTION IN FUNCTION OF ARM ...