The function S05 must be selected ON if a safety sensor in closing is installed.
Selecting this function
is valid for both Master and Slave operators.
The function S06 must be selected ON if a safety sensor in opening is installed.
Selecting this function
is valid for both Master and Slave operators.
·
The function S07 is displayed only if the function S05 = ON
Select ON if you have installed a safety sensor in closing
monitored (as required by standard
EN16005) to activate the test
sensor at the beginning of each closing cycle.
For more information, refer to par. "Safety sensors devices".
Select OFF if the safety sensor in closing is not
arranged to be monitored.
·
The function S08 is displayed only if the function S06 = ON
Select ON if you have installed a safety sensor in opening
monitored (as required by
standard EN16005) to activate the test
sensor at the beginning of each opening cycle.
For more information, refer to par. "Safety sensor devices".
Select OFF if the safety sensor in opening is not
arranged to be monitored.
·
The function S09 is displayed only if the function S07and/or S08 = ON.
Select the logical state of the test used to monitor the safety sensors.
The setting depends on the characteristics of the sensor.
Select OFF for sensors "4SAFE SW ON" or "OA-EDGE T.
Select ON for the sensor "TOP SCAN-S".
For more information, refer to par. "Safety sensor devices".
·
Configuration of the contact on the OPEN input between terminals 6-7 of the PWN-T board.
Select ON with normally open contact, or if you do not use
OPEN INPUT.
Select OFF if you are using a device with a normally closed contact.
·
The operators are now ready to start the set-up cycle.
Press the button (OK) to start the set-up cycle.
6. INITIAL SET-UP CYCLE
·
The Master operator starts opening at slow speed after 4 beeps of start signal. At the end of the opening cycle, a prolonged 3 seconds
beep, will signal the end of the Master operator set-up. The Master operator leaf remains opened to permit the set-up of the slave
operator.
·
The Slave operator starts opening at slow speed after 4 beeps of start signal. At the end of the opening cycle, a prolonged 3 seconds
beep, will signal the end of the Slave operator set-up.
·
The set-up is now completed, the closing cycle start automatically providing to close as first the slave operator and then after a delay
time the master operator.
Just for model SMT-B e SMT:
The set-up cycle of the operator without spring is fully operated by the motor, and so the function S02 must not take in to account.
The set-up steps for these operators are the following:
Slow opening of the Master operator and leaf hold in opening position;
Slow opening of the Slave operator ;
Slow closing of the Slave operator, prolonged 3 seconds beep at the end of the closing to signal the end of the Slave operator set-up.
Slow closing of the Master operator, prolonged 3 seconds beep at the end of the closing to signal the end of the Master operator set-up.