26.5) CONSIDERATION ON THE USE OF N-DSEL PROGRAMMER IN A DOUBLE DOOR SYSTEM.
With the digital programmer N-DSEL is possible to operate separately on operators Master and Slave as regards the following sections of
the programming menu and general area information.
a) FUNCTIONS AND PARAMETERS
pressing the F3 button you switch from Master to Slave and vice versa
Master operator
Slave operator
b) MAINTENANCE
pressing the F3 button you switch from Master to Slave and vice vers
a
Master operator
Slave operator
If the display shows the letter M on the N-DSEL operations it's related to the Master, if display show letter S operation performed it's related to
the slave operator.
c) INFO AREA AND MEMORY EVENTS
Also the informations and the events can be accessed individually.
Once you enter in the information menu as described in par. 20, press the
F3 button to selected on which operator you want to display information and events.
At the top right of the display will show the letter M if the
information regarding the Master operator, the letter S if they relate to the operator Slave.
pressing the F3 button you switch from Master to Slave and vice vers
a
Master operator
Slave operator
In double leaf application, reset error log first on SLAVE (S) unit and then on MASTER (M) unit.
To reset error log, select “ERROR RESET” and press OK.
55
Содержание Neptis SMP
Страница 8: ...5 TECHNICAL DRAWINGS 8 ...
Страница 9: ...9 ...
Страница 10: ...10 At door open a mechanical end stop has to be installed ...
Страница 11: ...11 At door open a mechanical end stop has to be installed ...
Страница 17: ...17 8 SELECTING THE OPENING DIRECTION IN FUNCTION OF ARM ...