FUNCTION STATUS
DESCRIPTION
*' SLAVE
OFF
Internal and external radars are deactivated during closing phase in "Night Lock" program
ON
Internal and external radars are activated during closing phase in "Night Lock" program, causing the door
reopening
OFF
Push button
F1
of digital selector N-DSEL enables door opening only during automatic program modes
ON
Push button
F1
of digital selector N-DSEL enables door opening both during automatic program modes and
during "Night Lock" program
OFF
Activates buzzer warning relative to the reached motor power limit (please check paragraph "Functional Testing")
ON
Deactivates buzzer warning relative to the reached motor power limit
F35
Function disabled
F36
Function disabled
F37
Function disabled
F38
Function disabled
F39
Function disabled
OFF
Cyclic function disabled
ON
Cyclic function. Activates the continuous door opening and closing cycle; this function is meant to be used for
function testing or laboratory purposes
S
*' For double leaf swing door application.
F32
F33
F34
F40
In the column Slave of the present spreadsheet, the functions marked with letter S, have to be
separately configured on Slave operator. All other functions not marked with letter S, have to be set on Master operator and are common for
both units.
34
Содержание Neptis SMP
Страница 8: ...5 TECHNICAL DRAWINGS 8 ...
Страница 9: ...9 ...
Страница 10: ...10 At door open a mechanical end stop has to be installed ...
Страница 11: ...11 At door open a mechanical end stop has to be installed ...
Страница 17: ...17 8 SELECTING THE OPENING DIRECTION IN FUNCTION OF ARM ...