PARAMETER
Ref. Drawing
DESCRIPTION
*'SLAVE
P29
P30
P31
Parameter disabled
P32
Parameter disabled
P33
*'
For double leaf swing door application.
In the column Slave of the present table, the functions marked with letter S,
have to be separately configured on Slave operator. All other functions not marked with letter S, have to be set on Master
operator and are common for both units.
S
S
Fig.5
S
P24
P25
P28
Safety sensor test time
(adjustment enabled if
F20
and/or
F21=ON
). This parameter
can be used only if safety sensors with test monitoring option checked by the control
unit are installed and in case the default value 0% caues safety test failure. For further
information please check paragraph "Safety Sensors".
P26
Deactivation time for Interlock system in case that one of the door cannot close
properly
(adjustment enabled if
F26=ON
). By 0% (default value) the function is disabled.
Increase this value to achieve a higher time after which the interlock function is disabled
if one of the two doors cannot close due to high flow of person walking through it.
At value 100% time is 2 minute. Please check paragraph "Interlock system".
P27
Opening acceleration ramp:
Increase this value for higher acceleration during
opening cycle.
P23
Wind stop at door open.
Increase this value to achieve a higher opposite force to wind
direction in order to keep door open.
37
This parameter allows you to select the number of cycles of opening/closing after which the
display of the program selector N-DSEL show the massage "
SCHEDULED
MAINTENANCE
".
OFF (default), the message is not displayed.
Select the number of cycles in dependence on the operations of the door and the conditions
of use:
8K (8000 cycles), 16K (16.000 cycles), 32K (32.000 cycles), 64K (64.000 cycles), 128K
(128.000 cycles), 256K (256.000 cycles), 512K (512.000 cycles).
S
Leaf braking intensity when the opening safety sensor trips
.
Increasing the value reduces the braking distance.
This parameter is not applicable for the NEPTIS SMP operator
This parameter is not applicable for the NEPTIS SMP operator
P34
P35
Breaking ramp at the end of opening upon a manual push
Increasing the value a leaf breaking is achieved.
This parameter is enabled only if the virtual closing spring has been activated by
parameter P30.
Distance from opening end run in which the door is breaking upon a manual
push
Increasing the value a higher distance from opening end run is achieved. Upon a
manual push the door leaf is breaking at the adjusted distance.
This parameter is enabled only if the virtual closing spring has been activated by
parameter P30.
S
S
Virtual spring for door closing
Closing the door after an opening by hand.
At default value = 00 the function is disabled and the door does not close after an opening
by hand.
Setting the value = 01 the door closes with minimum force.
Increase the value for higher force during reclosing.
S
Содержание Neptis SMP
Страница 8: ...5 TECHNICAL DRAWINGS 8 ...
Страница 9: ...9 ...
Страница 10: ...10 At door open a mechanical end stop has to be installed ...
Страница 11: ...11 At door open a mechanical end stop has to be installed ...
Страница 17: ...17 8 SELECTING THE OPENING DIRECTION IN FUNCTION OF ARM ...