In case of 230Vac mains voltage, put the 4-pole connector of the transformer primary in the J3 connector (230V) of PWN-T board (factory
setting).
!
In case of 115Vac mains power supply, put the 4-pole connector of the transformer primary in the J2 (115V) connector of PWN-T board.
TERMINAL BOARD M1
230 Vac power supply: phase to terminal F, neutral to terminal N, ground connection with terminal ground symbol.
!
Ground the operator by connecting the ground cable from the line to the Faston connector on the plate the PWN-T board is fastened to.
A cable, connected with ground terminal of PWN-T board, is connected with the second faston.
!
The electric line is protected by 2A fuse F1.
TERMINAL BOARD M2
Terminals 1-3-4
MANUAL PROGRAM SELECTOR, located on operator side panel (factory wiring):
closed contact on position I to terminal 1 (AUX1);
central contact to terminal 3 (common);
closed contact on position II to terminal 4 (AUX2);
!
For more information on the operating modes of manual program selector, refer to "Program selectors" paragraph.
Terminals 2-3
Input of SAFETY SENSOR FOR CLOSING, N.C. contact.
The operation of safety sensor for closing must be enabled by N-DSEL digital programmer (function F18 ON).
The activation during closing provokes the door reopening.
Terminals 5-7
Input of SAFETY SENSOR FOR OPENING, N.C. contact.
The operation of safety sensor for opening must be enabled by N-DSEL digital programmer (function F19 ON).
The activation during opening stops the door leaf movement; when the sensor deactivates, the opening restarts at low speed.
Terminals 6-7
OPEN input.
Input contact logic state can be selected as N.O. (default condition) or N.C. by N-DSEL digital programmer (function 30).
The activation allows opening the door of all operating programs.
11) PWN-T POWER SUPPLY MODULE AND ELECTRIC WIRING
VOLTAGE CHANGE
115V 230V
115/230V
GROUND
20
OPEN