15)
PROGRAM SELECTORS
The program selector allows the door user to select the operating mode.
The following can be used, according to the choice: manual selector integrated in Neptis SMP operator side, EV-MSEL key mechanical
selector or N-DSEL digital programmer.
Each program selector is described in details below.
= Bi-directional automatic program
The door automatically opens when each opening control activates.
= Free manual door
The automatic operation is disabled and door can be manually open.
= Night lock program
The door can only be open by OPEN input or radio control if EN/RF1 radio receiver is installed.
= Open door program
The door stops in complete opening position.
ELECTRIC CONNECTIONS
Terminal 1 of EV-MSEL= to terminal 9 (Internal radar) of Neptis SMP operator PWN-T.
Terminal 2 of EV-MSEL= to terminal 3 (Common) of Neptis SMP operator PWN-T.
Terminal 3 of EV-MSEL= to terminal 1 (AUX 1) of Neptis SMP operator PWN-T.
Terminal 4 of EV-MSEL= to terminal 4 (AUX 2) of Neptis SMP operator PWN-T.
15.2) EV-MSEL MECHANICAL KEY SELECTOR
5-position key mechanical selector can be used as an alternative to
the manual selector and its operation is enabled by F01 function OFF
(default preset).
The key can be taken out of the selector when in any position in order to prevent the work program from undesired changes.
Open door program
The door stops in complete opening position.
Free manual door
The automatic operation is disabled and door can be manually open.
Bi-directional automatic program
The door automatically opens when each opening control activates.
Single-direction automatic program output only
To exclude the incoming detection on external radar input
Night lock program
The door can only be open by OPEN input or radio control if EN/RF1 radio receiver is installed.
OPERATING MODE
Insert and rotate the key in EV-MSEL selector to select the program desired.
= no active symbol
and
and
Disconnect manual selector wires from terminal board of
PWN-T module if EV-MSEL mechanical selector is
installed.
27
15.1) MANUAL PROGRAM SELECTOR
The 3-position manual program selector is the basic solution provided for onboard operator.
The operation of this selector is enabled by F01 function OFF (default preset).
Position
I
Position
0
Position
II
if F07 function is set to
OFF
(default)
Position
II
if F07 function is set to
ON
For any check on proper connection and operation of key mechanical selector, enter inputs diagnostics (see par. 14.5) to ensure
that different key positions correspond to activation of the following symbols: