9) ELECTRIC ARRANGEMENTS
NOTE:
The grey part indicates the survey
zone of radar and sensors.
The number of cables and the
relevant section in mm is indicated
for every device.
2
3
4
5
6
7
EXTERNAL RADAR (4x0,5mm)
INTERNAL RADAR (4x0,5mm)
OPENING CONTROL (2x0,5mm)
PROGRAM SELECTOR (4x0,5mm)
SAFETY SENSOR FOR CLOSING (6x0,5mm)
SAFETY SENSOR FOR OPENING(6x0,5mm)
NEPTIS SMP OPERATOR (mains power supply 3x1,5mm)
ELECTRIC LOCK (2x1mm)
FLOOR STOP
8
9
!
The power supply line must be protected against short circuit and dispersion to ground.
!
On the power supply mains, provide for an omni-polar switch/selector with contact opening distance of at least of 3 mm.
!
Use self-extinguishing cables for electric connections.
!
Separate the mains power supply line from the very-low voltage line relative to control and safety accessories.
!
On the plastic side panels of the Neptis SMP operator there are the holes that must be broken open, through which the electric cables
must be inserted. The installer must made the power supply cable stable inside the operator and, particularly, limit the peeling of cable
primary sheath so that the air and surface distances are not reduced if a connector detaches from the terminal.
!
If operator is installed on a door leaf, perform electric connection by a branching box with suitable flexible unions and pipes, available on
the market.
1
7
5
6
4
3
8
1
9
2
ELECTRONIC SECTION