background image

Patented

LEVIT

ON

WARNING

TO 

PR

OTEC

T AG

AINS

T

EL

ECT

RONI

C SHOCK

 TES

T

BE

FORE 

EA

CH

 USE

.

1. PL

UG

 INT

O RE

CEPT

ACL

E.

2. IF

 LIGHT

 IS NO

T ON,

  PRES

S AN

D REL

EA

SE

  RESE

T B

UT

TON - L

IGHT

  S

HOUL

D COME ON

.

3. PR

ESS 

TES

T B

UT

TON - 

  LIGH

T M

US

T GO

 OF

F

4. P

RE

SS 

AN

D REL

EA

SE

  RESET

 BUT

TON 

AGAIN 

  FOR 

USE.

DO N

OT US

E IF

 TES

T FA

ILS

RAINPR

OO

F

DO

 NO

T IMMERSE

1L37

10

TES

T

TES

T

RES

ET

RES

ET

Kit Description

Retro-DWS is a tubular self-regulating heating system designed for use in 

4-inch and 3-inch non-pressurized sewage and waste water drain lines, as well 

as other large diameter non-pressurized pipes and storm drains. The core tube 

is constructed of HDPE (high density polyethylene) and will push inside most 

pipes for long distances. They can also be drawn in with a fish tape.
Retro-DWS utilizes a conductive polymer tubular heater technology which 

provides a barrier from the fluids while providing extremely efficient freeze 

protection. Retro-DWS can be used as a system to prevent freezing or as a 

precautionary system. If the drain waste or sewer freezes, the system can be 

energized to begin the thawing process.
Retro-DWS is supplied with all of the necessary fittings to fit a 4-inch or 3-inch 

pipe at a clean out or other entry point. The Retro-DWS can be easily adapted 

to fit larger pipe diameters if required by using readily available, industry stan-

dard components.
Available with Ground-Fault Protection (GFCI) or Cord-Set (CS) both in 

120 volt and 240 volt.

For installation of Retro-DWS into other applications refer to Retro-DWS 

Other Methods document.

LEVIT

ON

WARNING

TO P

ROT

ECT

 AG

AIN

ST

ELE

CTR

ONIC

 SH

OCK

 TES

T

BEF

ORE

 EAC

H U

SE.

1. P

LUG

 INT

O R

ECE

PTA

CLE

.

2. IF

 LIG

HT IS

 NO

T O

N,

  P

RES

S AN

D R

ELE

ASE

  R

ESE

T BU

TTO

N - L

IGH

T

  S

HOU

LD C

OM

E O

N.

3. P

RES

S TE

ST B

UTT

ON -

 

  LIG

HT M

UST

 GO

 OFF

4. P

RES

S AN

D R

ELE

ASE

  R

ESE

T BU

TTO

N AG

AIN

 

  FO

R U

SE.

DO N

OT U

SE IF

 TES

T FA

ILS

RAIN

PRO

OF

DO N

OT IM

MER

SE

1L37

10

TE

ST

TE

ST

RES

ET

RE

SE

T

LEVIT

ON

WARNING

TO P

ROT

ECT

 AG

AIN

ST

ELE

CTR

ONIC

 SH

OCK

 TES

T

BEF

ORE

 EAC

H U

SE.

1. P

LUG

 INT

O R

ECE

PTA

CLE

.

2. IF

 LIG

HT IS

 NO

T O

N,

  P

RES

S AN

D R

ELE

ASE

  R

ESE

T BU

TTO

N - L

IGH

T

  S

HOU

LD C

OM

E O

N.

3. P

RES

S TE

ST B

UTT

ON -

 

  LIG

HT M

UST

 GO

 OFF

4. P

RES

S AN

D R

ELE

ASE

  R

ESE

T BU

TTO

N AG

AIN

 

  FO

R U

SE.

DO N

OT U

SE IF

 TES

T FA

ILS

RAIN

PRO

OF

DO N

OT IM

MER

SE

1L37

10

TE

ST

TE

ST

RES

ET

RE

SE

T

Approvals

 

Usage Type W

 

Installation Type D USA

Table of Contents

General Information  . . . . . . . . . . . . . . . . . . . . . . . .  1

Warnings    .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   1

Kit Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . .  2

Ordering Chart . . . . . . . . . . . . . . . . . . . . . . . . . . .  2

Optional Accessories . . . . . . . . . . . . . . . . . . . . . . . .  2

Standard 4-inch Cleanout Instructions     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   3

Standard 3-inch Cleanout Instructions   . . . . . . . . . . . . . . .  5

Control Devices and Insulation Installation . . . . . . . . . . . . .  7

Electrical System Connection     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   9

Limited Warranty     .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   .   . 10

Extended Warranty Application Form . . . . . . . . . . . . . . . . 11

Important Safety Instructions and Rules

 for safe 

Installation and Operation

FIRE AND SHOCK HAZARD.

 This component is an electrical 

device which must be installed properly. Read and follow 

these rules and instructions carefully. Failure to follow them 

could result in serious bodily injury and/or property damage.

WHEN PERFORMING WORK OR REPAIRS ON YOUR 

WATER SYSTEM BE SURE TO UNPLUG YOUR HEAT-LINE 

SYSTEM FROM THE POWER SUPPLY.

•  Check your local building, plumbing and electrical codes 

before installing. You must comply with their rules. 

•  Do not force the Retro-DWS into the pipe to the point 

where the pipe creases and bends

•  Do not install the Retro-DWS interface connection in a 

manner which would render it non-serviceable.

•  Retro-DWS meets cCSAus codes for use in Canada and 

the United States.

•  Before installing this product have the electrical outlet 

checked by an electrician to make sure it is properly 

installed and grounded in accordance with your local 

Electrical Code.

•  Before installing or servicing your Retro-DWS 

BE 

CERTAIN

 that the power source is disconnected.

•  Do not use extension cords.

• 

This product is designed to keep drains from freezing 

in serious climate conditions. 

The Retro-DWS tube may 

obstruct certain materials, especially solids in the drains 

so a service schedule for proper maintenance is recom-

mended. 

The use of this product is at the sole discretion 

of the user. Heat-Line will not be liable for obstructions 

or blockages that may occur in some situations.

•  Never tamper with or alter the electrical apparatus associ-

ated with your Heat-Line system.

•  The Retro-DWS product is 

exclusively designed

 to be 

employed in 

non-pressurized

 plumbing drain, waste, and 

sewer pipe applications. It is not designed to be installed 

or operated in a pressurized application.

Retro-DWS

®

 

Internal Heating Cable System for  

Non-Pressurized Sewer and Waste Drain Pipes

Installation Instructions

Содержание Retro-DWS

Страница 1: ...ON LIGH T MUS T GO OFF 4 PRE SS AND REL EAS E RES ET BUT TON AGA IN FOR USE DO NOT USE IF TES T FAIL S RAIN PRO OF DO NOT IMM ERS E 1L37 10 TES T TES T RES ET RES ET Approvals Usage Type W Installation Type D USA Table of Contents General Information 1 Warnings 1 Kit Contents 2 Ordering Chart 2 Optional Accessories 2 Standard 4 inch Cleanout Instructions 3 Standard 3 inch Cleanout Instructions 5 C...

Страница 2: ... volt 460 ft 540 ft 8 watt 240 volt 300 ft 400 ft Length of Heater Product DWS 120 volt 100 130 volt Retro DWS DWS2 240 volt 208 277 volt Retro DWS Wattage 5 5 watts self regulating heater standard 8 8 watts self regulating heater Retro DWS Product Code Note Installers must provide 20 Amp circuit for Cord Set lengths greater than maximum lengths set for GFC L E V IT O N W A R N IN G TO PR OT EC T ...

Страница 3: ...rilled disolving ball point 5 1 Loosen the clamps on either end of the 4 flexible pipe coupler do not remove the clamps from their seated location on the flexible pipe coupler body Remove threaded cleanout plug CAUTION Effluent may be present when threaded cap is removed 2 Slide the flexible pipe coupler onto the now exposed spigot end of the male threaded adapter fitting and tighten the clamp to ...

Страница 4: ...ard industry practices test the integrity of the seal Note Be sure not to install the fitting interface and electrical in a manner which would render the system non serviceable L E V IT O N W A R N IN G TO PR OT EC T AG AI NS T EL EC TR ON IC SH OC K TE ST BE FO RE EA CH US E 1 PL UG IN TO RE CE PT AC LE 2 IF LI GH T IS NO T ON PR ES S AN D RE LE AS E RE SE T BU TT ON LI GH T SH OU LD CO M E ON 3 ...

Страница 5: ...ular heating cable sys tem into the pipe through the installed flexible coupler Note The pre drilled dissolving ballpoint is designed to reduce the friction of the Retro DWS tubular heater end seal during installation It also aids the passing of the tubular heater product through and around fittings located along length the pipe Remove threaded cleanout plug CAUTION Effluent may be present when th...

Страница 6: ...e Be sure not to install the fitting interface and electrical in a manner which would render the system non serviceable L E V IT O N W A R N IN G TO PR OT EC T AG AI NS T EL EC TR ON IC SH OC K TE ST BE FO RE EA CH US E 1 PL UG IN TO RE CE PT AC LE 2 IF LI GH T IS NO T ON PR ES S AN D RE LE AS E RE SE T BU TT ON LI GH T SH OU LD CO M E ON 3 PR ES S TE ST BU TT ON LI GH T M US T GO OF F 4 PR ES S A...

Страница 7: ...ciency Thermostats are used to duty cycle the system in an on off operation saving power consumption and maintain a certain pipe temperature A sensor lead must be placed on the coldest section of pipe Timers are used to duty cycle the system in an on off operation based on preset time intervals to save on power consumption Insulation is recommended for all new pipe installations even where the pip...

Страница 8: ...uit is intact and fully protected E Push reset button again and light will come ON This indicates that your Retro DWS is working F Follow this test procedure before each season and monthly while in use Your Retro DWS is now fully functional If at any time your Retro DWS system fails to work call your local electrician or Heat Line for assistance at 1 800 584 4944 Unplug when not in use Electrical ...

Страница 9: ...t wires through strain relief fitting supplied with the GFA STAT F Follow electrical guidelines per the GFA STAT FPT 130 manual included with your GFA STAT unit G Double check that the wires have been connected correctly H Establish power to the circuit and test reset the ground fault device for proper operation I Test the GFA STAT GFCI before each season and monthly while in use Your Retro DWS sy...

Страница 10: ...ent thereof without being obli gated to provide such a change or improvement for units sold and or shipped prior to such change or improvement WARRANTY EXCLUSIONS As to any Heat Line product after the expi ration of the time period of the warranty applicable thereto as set forth above There will be no warranties including any implied warranties of merchantability or fitness for any particular purp...

Страница 11: ...me Address Address City City Prov State Postal ZIP Prov State Postal ZIP Country Canada Other Country USA Home Phone Work Cell Email PRODUCT INFORMATION Product Cat Installation Type Sewage Grey water Drain Other Serial Length WARRANTY INFORMATION 5 Year Limited Warranty INCLUDED 10 Year Limited Warranty 1 75 foot 75 00 minimum PAYMENT DETAILS FOR 10 YEAR LIMITED WARRANTY System Length System Leng...

Страница 12: ... ground fault device and related electronics PRODUCT IMPROVEMENTS Heat Line reserves the right to change or improve its products or any component thereof without being obligated to provide such a change or improvement for units sold and or shipped prior to such change or improvement WARRANTY EXCLUSIONS As to any Heat Line product after the expira tion of the time period of the warranty applicable ...

Отзывы: