42
406388/F
2
On the
Setup
menu, select
Installation
.
Observe that the
Installation
dialog box opens.
3
Observe the
I/O Setup
page on the right side of the
Installation
dialog box.
4
Observe that the available serial interface ports on the computer are
listed.
Next to every port icon, a green indicator shows it is available,
while a red one shows it is not available.
5
Select the serial port the receiver is connected to.
6
In the
Select Input (COM)
dialog box, select the receiver you wish to connect to,
and then select
OK
Result
Every new interface is presented as a small "block diagram" on the
I/O Setup
page.
The block diagram shows you (from right towards
left) the serial port, the sensor receiver and the
hydrophone. The
I/O Setup
page also presents a
number of "inspection points". By selecting an inspection point you can retrieve relevant
information about the connection.
Related topics
Receiver dialog box, page 294
I/O Setup page, page 236
Defining the serial line communication parameters for navigation
sensors and external devices
Serial line communication with external devices is important for the TV80 system.
All serial line communication is based on specific transmission parameters. These
parameters must be defined at each end of the line, and they must be set up identical. By
means of the
Serial Port Setup
dialog box, you can define these parameters manually to
match fixed parameters on the peripheral device.
Prerequisites
•
The TV80 software is installed on the Processor Unit.
•
The new device is physically connected to the Processor Unit using a serial cable.
•
The communication parameters required for the device interface are known.
Simrad TV80 Reference Manual
Содержание Simrad TV80
Страница 1: ...kongsberg com simrad Simrad TV80 REFERENCE MANUAL ...
Страница 2: ......
Страница 353: ......
Страница 354: ... 2021 Kongsberg Maritime ...
Страница 355: ......
Страница 356: ...Reference Manual Simrad TV80 ...