background image

BLOOD GLUCOSE METER

Reference Manual

 

 

Содержание AVIVA COMBO

Страница 1: ...BLOOD GLUCOSE METER Reference Manual...

Страница 2: ......

Страница 3: ...se take the time to read this booklet carefully before you use your new meter To use it correctly and dependably you need to understand its operation screen displays and all individual features Should...

Страница 4: ...iva Meter with battery Accu Chek Aviva Test Strips and code chip Accu Chek Aviva Control Solution Any object coming into contact with human blood is a potential source of infection see Clinical and La...

Страница 5: ...all the Accu Chek Customer Careline on 0800 701000 UK or 1 800 709600 Ireland Please remember to complete the warranty card and send it by post to Roche Diagnostics so you receive the best customer se...

Страница 6: ...one If you have followed the steps in the booklet but still have symptoms that do not seem to match your test results or if you have questions talk to your healthcare professional The Accu Chek Multic...

Страница 7: ...2 Testing Your Blood Glucose 15 Performing a Blood Glucose Test 15 Flagging Test Results 20 Alternative Site Testing AST 21 Chapter 3 Meter Memory Setup and Downloading 29 Memory 29 Meter Setup 31 Set...

Страница 8: ...sting Blood Glucose in Multiple Patients 56 Testing Blood Glucose 58 Disinfecting the Meter 62 What to Disinfect 62 How to Disinfect 62 When to Disinfect 63 Suitable Disinfecting Cleaning Solutions 63...

Страница 9: ...ons 80 Additional Supplies 81 Information for Healthcare Professionals Alternative Site Testing AST 82 Chapter 8 The Accu Chek Multiclix Finger Pricker 83 Loading a Lancet Drum 85 Taking a Fingertip B...

Страница 10: ...nter memory adjust settings and scroll through results Test Strip Slot Insert test strip here Infrared IR Window Transfers data from the meter to a computer or PDA On Off Set Button Turns the meter on...

Страница 11: ...th symbol facing up Test Strip Container Control Solution Bottle Golden End Insert this end of the test strip into the meter Yellow Window Touch blood drop or control solution here Test Strip Top View...

Страница 12: ...over 3 Remove the old code chip if there is one in the meter and discard it Coding the Meter Inserting the code chip sets the meter to match the test strips This codes the meter Change the code chip e...

Страница 13: ...the code chip slot until it stops 5 Leave the code chip in the meter until you open a new box of test strips Notes Do not force the code chip into the meter it is designed to go into the meter only o...

Страница 14: ...or if you want to download your results to a computer 1 Press and release to turn the meter on The time and date appear on the display Set up and the hour flash 2 Press and release or to decrease or i...

Страница 15: ...ar 6 Once you set the year press and hold until the flashing test strip symbol appears The time and date are now set 7 See Chapter 3 Meter Setup to set other options Note When you install a new batter...

Страница 16: ...strip immediately after you take it out of the container Be sure to check the expiry date on the test strip container Do not use the test strips after that date Store the test strip container and met...

Страница 17: ...ger Pricker is intended for patient self monitoring by a single person only It must not be used to collect blood from more than one person as this poses an infection risk Any object coming into contac...

Страница 18: ...manufacturer s instructions 3 Insert the test strip into the meter in the direction of the arrows The meter turns on automatically 4 Make sure the code number on the display matches the code number on...

Страница 19: ...fly to allow blood to flow to your fingertips 7 Obtain a blood sample with the aid of the finger pricker Blood samples taken from the palm are equivalent to blood taken from the fingertip For detailed...

Страница 20: ...of blood This helps you get a blood drop 9 Touch the blood drop to the front edge of the yellow window of the test strip Do not put blood on top of the test strip When you see flash you have enough b...

Страница 21: ...t after each test Blood glucose results are displayed in mmol L If your meter displays mg dL call the Accu Chek Customer Careline on 0800 701000 UK or 1 800 7096000 Ireland Using the wrong meter can c...

Страница 22: ...fter performing exercise When you review the results in the meter memory this flag can help you remember what was different about the result Here is how to flag a result 1 Perform a test 2 With the te...

Страница 23: ...me to measure blood glucose If blood from an alternative site forearm upper arm thigh or calf is used there are certain times when testing is not appropriate see next page This is because your glucose...

Страница 24: ...when your blood glucose is low During peak action time of short acting insulin or rapid acting insulin analogues Up to two hours after injecting a short acting insulin or a rapid acting insulin analo...

Страница 25: ...e converter cap and following the standard procedure 2 Insert the test strip into the meter in the direction of the arrows The meter turns on automatically 3 Make sure the code number on the display m...

Страница 26: ...p symbol appear on the display 5 Press the finger pricker firmly against a fleshy area on the alternative site Press the finger pricker up and down in a slow pumping motion to assist the flow of blood...

Страница 27: ...d drop to the front edge of the yellow window of the test strip When you see flash you have enough blood in the test strip If you applied a blood sample but do not see the flashing you may reapply mor...

Страница 28: ...or some time Repeat the test with a new test strip Repeat the test with a properly stored test strip Unusual Test Results If your blood glucose result does not match how you feel follow these steps 26...

Страница 29: ...Read Chapter 2 Testing Your Blood Glucose and test again If you still have problems call the Accu Chek Customer Careline on 0800 701000 UK or 1 800 709600 Ireland If they do not match insert the corre...

Страница 30: ...d glucose hyperglycemia fatigue increased appetite or thirst frequent urination blurred vision headache or general aching Low blood glucose hypoglycemia sweating trembling blurred vision rapid heartbe...

Страница 31: ...based on one individual result in memory The memory is not lost when you replace the battery You do need to check that the time and date are correct after you replace the battery See Chapter 1 Adjusti...

Страница 32: ...Viewing Test Results Press either or to enter memory The most recent result appears Press to view previous results in order OR Press to look at the 7 14 or 30 day averages in that order 30...

Страница 33: ...r a reminder to test Hypo alarm select on or off If you choose on choose the blood glucose level for the alarm Using the set up mode is easy The has three functions for the set up mode With the meter...

Страница 34: ...level You are here decrease increase 1 Press to turn the meter on The flashing test strip symbol appears 2 Enter the set up mode press and hold for about four seconds Set up and the hour flash on the...

Страница 35: ...4 Press and release to set the hour The minutes flash 5 Press and release or to adjust the minutes Press to set the minutes Note Press and hold or down to scroll faster decrease increase 33...

Страница 36: ...at to set the day month and year 7 If you want to set up more options press and release If you want to exit press and hold until you see the flashing test strip symbol Setting the Time and Date contin...

Страница 37: ...ou prefer this will not affect your test results The beeper is helpful because it prompts you To apply blood or control solution to the test strip When enough blood or control solution is drawn into t...

Страница 38: ...eter on The flashing test strip symbol appears 2 Enter the set up mode press and hold for about four seconds Set up and the hour flash on the display 3 Press and release repeatedly until you reach the...

Страница 39: ...4 Press or to switch between On or OFF 5 If you want to set up more options press and release If you want to exit press and hold until you see the flashing test strip symbol 37...

Страница 40: ...tton You must have the beeper set to On for the alarm to sound Your new meter is preset with the alarm clock function set to OFF You must turn it On to use this feature If you turn A 1 A 2 A 3 and A 4...

Страница 41: ...lashes continuously 1 Press to turn the meter on The flashing test strip symbol appears 2 Enter the set up mode press and hold for about four seconds Set up and the hour flash on the display 3 Press a...

Страница 42: ...ress and release or to switch between On or OFF Press and release to set your choice 5 If you select On the hour flashes A 1 and the bell symbol remain on the display 6 Press and release or to select...

Страница 43: ...se are the only choices 8 Press and release to set the minutes 9 The next alarm A 2 and set up flash on the display with OFF and the bell symbol You can either set a second alarm or press and hold unt...

Страница 44: ...bol appears You can set the meter to let you know when your blood glucose is possibly too low You can also select what blood glucose level you want this alarm to have 3 3 to 4 4 mmol L Before you set...

Страница 45: ...out four seconds Set up and the hour flash on the display 3 Press and release repeatedly until you reach the display with OFF and the flashing set up and 4 Press and release or to switch between On an...

Страница 46: ...h The display shows 3 9 mmol L 6 Press and release or to select the level you want Press and release to set it 7 Press and hold until you see the flashing test strip symbol to exit the set up mode Thi...

Страница 47: ...nsfer the results to a computer connect the infrared meter cable according to the instructions 2 Run the software program and follow the instructions about how to download information Make sure the so...

Страница 48: ...is complete Notes If the data did not transfer successfully try again If you still have problems call the Accu Chek Customer Careline on 0800 701000 UK or 1 800 709600 Ireland To make the most of the...

Страница 49: ...s You should perform a control test when You open a new box of test strips You left the test strip container open You want to check the performance of the meter and test strips Your test strips were s...

Страница 50: ...e the date you opened the bottle on the bottle label The solution can be used for three months from that date or until the expiry date on the bottle label whichever comes first Do not use control solu...

Страница 51: ...is printed on the bottle label 1 Insert the test strip into the meter in the direction of the arrows The meter turns on automatically 2 Make sure the code number on the display matches the code numbe...

Страница 52: ...ion you want to test You will enter the level later in the test 4 Put the meter on a flat surface like a table 5 Remove the control bottle cap Wipe the tip of the bottle with a tissue OR Performing a...

Страница 53: ...sh you have enough control solution in the test strip Wipe the tip of the bottle with a tissue then cap the bottle tightly 7 The result appears on the display along with the control bottle symbol and...

Страница 54: ...ult alternate on the display if the result is in range The range is printed on the test strip container label Err and the control result alternate on the display if the result is not in range Remove a...

Страница 55: ...s the acceptable ranges for both the Level 1 and Level 2 control solutions The result you get should be inside this range Make sure you compare the result to the correct level of control When the cont...

Страница 56: ...of the container for a long time 5 Check if the test strips and control solutions were stored in a cool dry place Action Discard the test strips or control solutions if either is past the expiry date...

Страница 57: ...hapter 4 Control Testing and test again If you still have problems call the Accu Chek Customer Careline on 0800 701000 UK or 1 800 709600 Ireland If you chose the wrong control solution level you can...

Страница 58: ...w the recognised procedures for handling objects that are potentially contaminated with human material Practice the health and safety policy of your laboratory or institution Also to prevent contamina...

Страница 59: ...be used to test any other patient The Accu Chek Multiclix Finger Pricker is intended for patient self monitoring by a single person only It must not be used to collect blood from more than one person...

Страница 60: ...ger pricker that is approved for use by healthcare professionals 4 Use a finger pricker with adjustable penetration depth settings If using the Accu Chek Safe T Pro Plus sterile single use lancing dev...

Страница 61: ...ssure massage the finger towards the fingertip to encourage a drop of blood to form A proper but nevertheless small drop of blood approx 0 6 L must form 10 Immediately after the drop of blood has form...

Страница 62: ...blood in the test strip If you applied blood but do not see the flashing you may reapply more blood if applied IMMEDIATELY 13 The result appears on the display 14 Remove and discard the used test str...

Страница 63: ...est using the drop of blood that forms again at the puncture site Residues of water or disinfectant on the skin can dilute the drop of blood producing false results After a successful test the meter t...

Страница 64: ...of the meter may be disinfected The area around the test strip slot The display screen The outer casing How to Disinfect Make sure the meter is off Gently wipe the meter s surface Cotton buds wipes an...

Страница 65: ...lay If there is blood on the meter wipe the meter If blood has entered the meter wipe the area around the test strip slot and the display screen Allow areas you have wiped time to dry thoroughly The m...

Страница 66: ...Battery 1 Open the battery door on the back of the meter by pushing the tab in the direction of the arrow and pulling the door up Remove the old battery 2 Insert the new battery with the side up 3 Pu...

Страница 67: ...many stores It is a good idea to have a spare battery available Be sure the battery goes in side up or facing you After you change the battery the meter prompts you to confirm the meter s time and da...

Страница 68: ...urface with a soft cloth slightly dampened wring out any excess liquid with one of these cleaning solutions Super Sani Cloth 70 isopropyl alcohol Mild washing up liquid mixed with water 10 household b...

Страница 69: ...roubleshooting If you drop the meter or think it is not giving accurate results call the Accu Chek Customer Careline on 0800 701000 UK or 1 800 709600 Ireland To make sure the display is working prope...

Страница 70: ...K or 1 800 709600 Ireland The meter will not turn on or the display is blank Battery is dead Insert new battery Display is damaged Call the Accu Chek Customer Careline on 0800 701000 UK or 1 800 70960...

Страница 71: ...See Chapter 6 Changing the Battery The meter is in set up mode waiting for you to change or confirm settings See Chapter 3 Meter Setup The meter is ready for you to insert a test strip The meter is re...

Страница 72: ...the measuring range of the system Blood glucose may be lower than the measuring range of the system The test result was flagged See Chapter 2 Flagging Test Results Blood glucose is below the defined...

Страница 73: ...current month Before the end of the month insert a new code chip from a new box of test strips and ensure the code chip number matches the code number on the test strip container Make sure the time a...

Страница 74: ...remove the test strip and reinsert it or replace it if damaged If the message reappears call the Accu Chek Customer Careline on 0800 701000 UK or 1 800 709600 Ireland The code chip is incorrect Turn...

Страница 75: ...me and date in the meter are correct Blood or control solution was applied to the test strip before the flashing blood drop symbol appeared on the display Discard the test strip and repeat the test An...

Страница 76: ...five minutes and repeat the test Do not artificially heat or cool the meter The battery is almost out of power Change the battery now See Chapter 6 Changing the Battery The time and date settings may...

Страница 77: ...llary whole blood Measuring time 5 seconds Measuring range 0 6 to 33 3 mmol L Test strip storage conditions 2 C to 32 C Meter storage conditions Temperature 25 C to 70 C System operating conditions 6...

Страница 78: ...tic patients method comparison accuracy venous blood repeatability and control solution reproducibility The system is calibrated with venous blood containing various levels of glucose The reference va...

Страница 79: ...ls are present Disposing of the Meter During blood glucose measurement the meter itself may come into contact with blood Used meters therefore carry a risk of infection Please dispose of your used met...

Страница 80: ...refer to accompanying documents Please refer to safety related notes in the manual accompanying this instrument Store at Manufacturer Catalogue number Listed by Underwriter s Laboratories Inc in accor...

Страница 81: ...u Chek Multiclix Finger Pricker you will encounter the following symbols shown here with their meaning For single use only Use by Expiry Date Lot number Sterilized using irradiation with at least 25 k...

Страница 82: ...ry and other rights This manufacturer s warranty is in addition to any statutory or other rights which may be acquired by the customer through his dealings with the meter supplier The statutory provis...

Страница 83: ...x RH15 9RY Guarantee The statutory provisions on rights in consumer goods sales in the country of purchase shall apply Additional Supplies Test strips are available from your local Pharmacist only and...

Страница 84: ...tration and blood perfusion throughout the body can lead to sample site to site differences in glucose results These physiological effects vary between individuals and can vary within a single individ...

Страница 85: ...Accu Chek Multiclix Finger Pricker Comfort Dial with Depth Selection Cap Finger Pricker Release Button Priming Button New Lancet Drum AST Converter Cap for alternative site testing Lancet Counter Dept...

Страница 86: ...n the body not the fingertip The blue cap is for fingertip testing only The Accu Chek Multiclix Finger Pricker continued 84 Any object coming into contact with human blood is a potential source of inf...

Страница 87: ...used drum has two visible red stripes and the blue ring can rotate on the white drum You cannot insert a used drum into the finger pricker A new drum has a blue ring that does not move 1 Place your t...

Страница 88: ...il it clicks into place 3 Align the notch on the cap with the notch on the device and slide the cap on until it stops 4 You are now ready to use the first lancet The lancet counter shows five white ba...

Страница 89: ...netration Twist the comfort dial to adjust the setting Start at 2 or 3 for soft skin Try a higher setting if your skin is calloused or thick 6 Press the priming button like a pen until it clicks The r...

Страница 90: ...ess the yellow release button 3 Load the next lancet by twisting the plunger one quarter turn forward until it stops then back again The lancet counter decreases by one white bar For safety reasons on...

Страница 91: ...the cap by pulling it straight off It is not a twist cap 2 Align the notch on the converter cap with the notch on the finger pricker and slide the cap on until it stops 3 Dial the depth setting to 5 1...

Страница 92: ...the release button while pressing the priming button 5 Press the finger pricker firmly against a fleshy site and press the yellow release button Immediately lift the finger pricker off the site Remove...

Страница 93: ...7 Load the next lancet by twisting the plunger one quarter turn forward until it stops then back again The lancet counter decreases by one white bar For safety reasons once you advance to a new lance...

Страница 94: ...ngertip Blood obtained from a fingertip or palm fleshy part of the hand under the thumb thenar and the little finger hypothenar can be used at any time to measure blood glucose If blood from an altern...

Страница 95: ...e professional about Alternative Site Testing Treatment of the Puncture Site Wipe the puncture site with a clean dry tissue If it continues to bleed apply gentle pressure to the site with a plaster to...

Страница 96: ...ur healthcare professional Alternative site testing may be done Immediately before a meal Fasting DO NOT test from an alternative site Two hours or less after eating After exercising If you are sick I...

Страница 97: ...rd surface the lancets may protrude slightly from the drum If you drop a drum always pick it up at the red striped end 1 Place your thumb to the side of the notch and remove the cap by pulling it stra...

Страница 98: ...east once a week clean the finger pricker and inside of the cap with a cloth or cotton bud moistened with 70 ethanol or 70 isopropanol available in pharmacies Air dry thoroughly DO NOT Dip the cap in...

Страница 99: ...ing 49 control test results 53 control test unacceptable range 53 display check 67 disposing of the meter 77 error messages 68 74 expiry date 14 48 fatigue 28 flagging test results 20 frequent urinati...

Страница 100: ...98 thirst increased 28 time and date setting 32 tingling 28 trembling 28 troubleshooting 68 74 warranty 80...

Страница 101: ...Ireland Please have your Accu Chek Aviva Meter Accu Chek Aviva Test Strips and Accu Chek Aviva Control Solutions available when you call IMPORTANT READ CAREFULLY BEFORE USE GUARANTEE The statutory pr...

Страница 102: ...llowing patents British Patent Nos 0 505 504 and 2187191 and European Patent No 0 505 504 British Patent No 2187191 is licensed from Quadrant Holdings Cambridge Limited The Accu Chek Multiclix Finger...

Страница 103: ......

Страница 104: ...reserved 04886046001 02 0907 Roche Diagnostics GmbH 68298 Mannheim Germany www accu chek com ACCU CHEK ACCU CHEK MULTICLIX and ACCU CHEK AVIVA are trademarks of Roche All other product names and trade...

Отзывы: