144
406388/F
7
In the gear illustration, select the location of the sensor.
8
Select the direction the sensor is going to point to, either to the vessel or to the trawl.
9
Choose the measurements you want the sensor to make and define the relevant
parameters.
10
Select the update interval.
11
Select the relevant value for output power.
12
Select the communication
Channel
.
This is specially important if you wish to use several sensors to operate on
different communication channels. This is also important to avoid interference if
several vessels equipped with identical catch monitoring systems are operating
simultaneously in the same area.
13
Select
Program Sensor
to transfer the chosen parameters to the sensor.
14
In the
Sensor list
page, verify if the sensor appears with the correct parameters.
15
Disconnect the sensor from the interface cable and the computer.
Result
The sensor is configured for use.
Related topics
PX TrawlEye Configurator dialog box, page 266
Adding more measurements to a PX family sensor
The
Unlock Measurements
dialog box allows you to unlock extra measurements you
want your catch monitoring sensor to take.
Prerequisites
An additional license is required if you wish to make more than two measurements. To
obtain a license, contact your local dealer.
Context
This procedure applies to the following catch monitoring sensors:
• PX MultiSensor Mk2
• PX MultiCatch
• PX Universal
• PX Flow
By default, PX MultiSensor Mk2, PX Universal, PX MultiCatch and PX Flow sensors
can make 2 measurements. When interfacing a SR type receiver unit, PX MultiSensor
Mk2, PX Universal and PX MultiCatch sensors can make up to five measurements.