NOTICE
• Do not disassemble any devices of the DEF System other than the filter for change. Do not modify
any devices of the DEF System.
• Paint may cause deterioration of the devices. When painting the surrounding areas, take care not to
get any paint on the injector and the supply pump.
• Always use DEF that conforms to the quality standard. If any additional additive agents or water is
mixed in DEF and that mixture is used, the devices will not function properly, and conformance to
the exhaust gas regulations will be lost. In addition, it may cause failures in the engine system. If
DEF out of the standard is filled or used by mistake, contact your Komatsu distributor.
About the operation of Urea SCR system
The Urea SCR System automatically starts operating as soon as the engine is started.
Even after the engine starting switch is turned to the OFF position, the devices will still be in operation for sever-
al minutes to purge any DEF in the lines, the injector and the supply pump back to the DEF tank. It does not
indicate any abnormality. When DEF has been returned to the tank, the devices stop.
Do not turn OFF the battery disconnect switch while the devices are still in operation. When the devices com-
plete their shutdown process, the system operating lamp will go out, and the battery disconnect switch may be
disconnected.
About the operation in cold weather
DEF freezes at –11 °C.
Urea SCR system is equipped with a heating system to thaw frozen DEF once it is frozen, for example, during
parking and to prevent DEF from freezing during operation.
In case DEF freezes during parking, once the engine starts running the heating system automatically starts pro-
viding heat to thaw frozen DEF. The pump and the injector start working only after a proper amount of DEF is
thawed. This may be noticed as a delay in the start of functioning of the pump and the injector.
The heating system is also activated automatically during operation to prevent DEF from freezing whenever the
ambient temperature drops below a certain threshold where DEF in the system may freeze. In the event that the
ambient temperature drops further than a temperature where the heating system is capable of maintaining fluidi-
ty of DEF, the DEF system automatically starts purging the remaining DEF back to the tank and stops pumping
and injection while heating continues. Once the ambient temperature rises above a temperature where DEF
system becomes functional, it resumes operation automatically.
Short duration of white plume given off from the tail pipe may be visible at and shortly after engine start-up in
cold weather, but this is not malfunction.
Inducement strategy when the DEF tank Level becomes low
When the amount of DEF fluid in the tank goes low, the Inducement strategy will be activated.
If Inducement starts, add DEF to the DEF tank immediately.
The DEF level caution lamp (1) on the monitor lights up, the
audible alert starts, and the Action level is displayed, and In-
ducement strategy is activated. Inducement strategy includes
engine output deration, speed limitation, or other warning ac-
tions intend to prompt the operator to maintain or repair SCR
system. The Inducement strategy progresses in 4 levels from
Warning, Continuous Warning, Low level Inducement and Se-
vere Inducement.The DEF level caution lamp (1) on the ma-
chine monitor will light up, audible alert will start, then Action
level will be displayed on the machine monitor, and engine
power will be derated in steps.
In Action Level “L03 (Low level Inducement)” and “L04 (Severe Inducement)” engine power will be derated.
When Action Level “03” or “04” is displayed, move the machine to a safe place and add DEF.
The content of the warning can be checked on the “SCR Information” screen of the user menu.
OPERATION
EXPLANATION OF COMPONENTS
3-143
Содержание WA380-8
Страница 2: ... ...
Страница 20: ......
Страница 25: ...LOCATION OF SAFETY LABELS SAFETY SAFETY LABELS 2 5 ...
Страница 64: ......
Страница 65: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 158: ...SWITCHES g0038111 1 ECSS switch 2 Front working lamp switch EXPLANATION OF COMPONENTS OPERATION 3 94 ...
Страница 300: ...Securing position Fixing angle A 66 B 30 C 26 D 30 Expected trailer width E 2990 mm TRANSPORTATION OPERATION 3 236 ...
Страница 321: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 391: ...Viewed from the rear side of the machine MAINTENANCE MAINTENANCE PROCEDURE 4 71 ...
Страница 395: ...SPECIFICATIONS 5 1 ...
Страница 397: ... 1 Value when bucket dump angle is 45 SPECIFICATIONS SPECIFICATIONS 5 3 ...
Страница 400: ......
Страница 416: ......
Страница 417: ...REPLACEMENT PARTS 7 1 ...
Страница 424: ......