• When the turbo protect function is actuated, the engine speed is held at approximately 1000 rpm or less,
regardless of the position of the fuel control dial.
• When the turbo protect function is actuated, the engine speed is held at approximately 1000 rpm or less,
even if the fuel control dial is operated.
• When the turbo protect function is canceled, the engine speed is set to the speed for the position of the fuel
control dial.
• The actuation time of the turbo protect function is limited to 20 seconds.
AMBIENT TEMPERATURE RANGE FOR OPERATION AND STORAGE
• The recommended ambient temperature range for operation and storage is -20 to +45 °C.
• When operating in ambient below 0 °C, refer to "COLD WEATHER OPERATIONS" for details of precau-
tions.
METHOD FOR OPERATIONS AND CHECKS AFTER STARTING ENGINE
k
k
WARNING
• If there has been any emergency stop, abnormal ac-
tuation or trouble, turn the starting switch key to OFF
position.
• Do not perform operations nor operate the levers or
pedal abruptly while the hydraulic oil is at low temper-
ature. Always perform the warm-up operation for the
hydraulic equipment until the hydraulic oil tempera-
ture caution lamp displays the correct temperature.
When the hydraulic oil temperature is low, the low
temperature display shown in the figure is given.
• Display (A) when temperature is correct: Caution
lamp background (C) is blue.
• Display (B) when temperature is low: Caution lamp
background (C) is white.
• If the warm-up operation for the hydraulic equipment
is not performed thoroughly, and the machine is
moved, the reaction of the machine to the operation of
the control levers and pedals will be slow and the
movement of the machine may not be what the opera-
tor intended. Particularly in a cold weather, be sure the
warm-up operation is completed.
• Keep away from the exhaust pipe while the engine is
running and immediately after stopping the engine.
Keep combustible materials away from the exhaust
pipe outlet.
There are 2 types of warm-up operation: warm-up of the engine and warm-up of the hydraulic equipment. In
addition, depending on the environment, the method of performing the warm-up operation may differ, so perform
the warm-up operation according to the descriptions given in the appropriate section.
The hydraulic equipment is not warmed by simply performing engine warm-up operation. Perform the warm-up
operations for the hydraulic equipment and engine separately. Warm-up of the hydraulic equipment thoroughly
ensures that the hydraulic oil is warmed up and that warm hydraulic oil circulates in all the control circuits.
METHOD FOR CHECKING STARTING CONDITION AND UNUSUAL NOISE OF
ENGINE
• When starting the engine, check that the engine causes no abnormal noise and that it starts up easily and
smoothly.
MACHINE OPERATIONS AND CONTROLS
OPERATION
3-166
Содержание PC700LC-11
Страница 2: ......
Страница 23: ...LOCATION OF SAFETY LABELS 5 SAFETY SAFETY LABELS 2 3...
Страница 66: ......
Страница 67: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1...
Страница 73: ...REMARK The above figure does not show all of the caution lamp symbols OPERATION GENERAL VIEW 3 7...
Страница 316: ......
Страница 317: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1...
Страница 331: ...Fuel main fil ter cartridge Replace Replace Replace Replace MAINTENANCE MAINTENANCE SCHEDULE 4 15...
Страница 375: ...A Important inspection part F Front Revolving frame Center frame MAINTENANCE MAINTENANCE PROCEDURE 4 59...
Страница 396: ......
Страница 397: ...SPECIFICATIONS 5 1...
Страница 401: ...For 7 6m Boom SPECIFICATIONS SPECIFICATIONS 5 5...
Страница 402: ...SPECIFICATIONS SPECIFICATIONS 5 6...
Страница 426: ......
Страница 427: ...REPLACEMENT PARTS 7 1...
Страница 434: ......
Страница 442: ...PC700LC 11 HYDRAULIC EXCAVATOR Form No UENAM01321 2017 KOMATSU All Rights Reserved Printed in Belgium 09 2017...