BREAKER MODE SWITCH
k
k
WARNING
When operating breaker using breaker switch, lock the pedal with the lock pin to avoid accidental oper-
ation.
When you operate attachment, the screen will switch to the screen including bird's eye view automati-
cally.
The breaker mode switch operates the breaker.
Press the breaker mode switch to operate breaker and release
to stop.
METHOD FOR CHANGE-OVER AND CONNECT HYDRAULIC CIRCUIT FOR
MACHINE READY FOR INSTALLATION OF ATTACHMENT
NOTICE
• The return circuit when a breaker is installed must return directly to the return filter, so do not use it
in the mode other than B mode.
• The standard set pressure of the safety valve of the service valve is 20.6 MPa {210 kg/cm
2
} if you
select B mode set at the shipment from the plant and it becomes 27.4 MPa {280 kg/cm
2
} when ATT/P
or ATT/E mode is selected. Depending on the attachment, it may be necessary to adjust the pres-
sure. Ask your Komatsu distributor for the adjustment.
• When the attachment control is installed to the machine, select the attachment mode of which the
setting pressure is applicable for the attachment, or the breaker mode. If the attachment mode of
which the setting pressure is applicable for the attachment is not available on the machine monitor,
consult your Komatsu distributor for the pressure setting.
SWITCHING THE HYDRAULIC CIRCUIT
• Depending on the type of attachment, set the working mode on the monitor as follows.
• The hydraulic circuit and the set pressure of the safety valve in the service valve switch according to the
working mode selected.
Attachment
Working mode
Hydraulic circuit
Set pressure of safety valve
of service valve
Breaker or attachment with
one-way circuit
B mode
Return circuit automatically
becomes the circuit that
does not pass through con-
trol valve
When shipped from factory:
20.6 MPa {210 kg/cm
2
}
Crusher or other attach-
ment with two-way circuit
ATT/P or ATT/E mode
Return circuit automatically
becomes the circuit that
does not pass through con-
trol valve
When shipped from factory:
27.4 MPa {280 kg/cm
2
}
Depending on the attachment, it is necessary to change the oil flow in the service circuit.
For details of setting the oil flow , see “METHOD FOR OPERATING ATTACHMENT”
SWITCHING OF BREAKER AND GENERAL ATTACHMENT
ATTACHMENTS AND OPTIONS
HANDLE MACHINE READY FOR INSTALLATION OF ATTACHMENT
6-41
Содержание PC210-11
Страница 2: ......
Страница 24: ......
Страница 74: ......
Страница 75: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 352: ......
Страница 353: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 431: ...SPECIFICATIONS 5 1 ...
Страница 435: ...PC210LC 11 PC210NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Страница 436: ...PC230NHD 11 SPECIFICATIONS SPECIFICATIONS 5 6 ...
Страница 458: ...PC210 11 2 Piece Boom PC210LC 11 2 Piece Boom PC210NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 22 ...
Страница 459: ...PC230NHD 11 2 Piece Boom ATTACHMENTS AND OPTIONS 2 PIECE BOOM 6 23 ...
Страница 470: ... Not including tail swing SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 34 ...
Страница 505: ...REPLACEMENT PARTS 7 1 ...
Страница 521: ......