a
b
KDPF Filter Cleaning
4500
Hydraulic Oil Change
5000
a: Maintenance items
b: Default maintenance interval settings (h)
c: Time remaining until maintenance (h)
*1:
When using engine oil for cold district, the maintenance interval setting must be changed. For details of the oil,
see “RECOMMENDED FUEL, COOLANT, AND LUBRICANT (7-5)”.
On the “Maintenance” menu screen, it is possible to perform
the following operations with switches F1 to F6.
F1, F2: Moves to the right and left menus.
F3: Moves to the next item (1 line below). When on the last
line, it moves to the first line.
F4: Moves to the previous item (1 line above). When on the
first line, it moves to the last line.
F5: Returns the screen to the standard screen.
F6: If this switch is kept pressed, the screen changes to the
screen for resetting the remaining time to the maintenance
for the selected item.
REMARK
When resetting the remaining time to the maintenance, keep switch F6 pressed for at least 1.5 seconds. If this
time is short, the switch operating sound can be heard, but the screen does not switch to the screen for reset-
ting the remaining time to the maintenance.
• If no switch is operated for 30 seconds on the “Maintenance” menu screen, the screen automatically returns
to the standard screen.
• When the maintenance time caution lamp is lit on the standard screen, press F6 on the standard screen
and the screen automatically displays the “Maintenance” menu screen.
• On the “Maintenance” menu screen, if the time remaining to the maintenance for any item is less than 30
hours (initial setting value), the remaining time display (c) is highlighted in yellow. If the time remaining to
the maintenance is less than 0 hour, display (c) is highlighted in red.
• If you want to change the setting for the maintenance time or maintenance notice time (initial setting: 30
hours), consult your Komatsu distributor.
Operations on the “Maintenance Due Time Reset” screen
On the “Maintenance” menu screen, if switch F6 is kept pressed for at least 1.5 seconds, the screen changes to
the “Maintenance Due Time Reset” screen.
Reset the remaining time to the maintenance on this screen.
1.
Press switch F6 when the “Maintenance Due Time Reset”
screen is in the condition shown in the figure. The screen
switches to the reconfirmation screen.
REMARK
• When canceling the reset, press switch F5. The
screen returns to the “Maintenance” menu screen.
• On the reset screen, if no switch is operated for more
than 30 seconds, the screen automatically changes to
the “Maintenance” menu screen.
EXPLANATION OF COMPONENTS
OPERATION
3-76
Содержание PC210-11
Страница 2: ......
Страница 24: ......
Страница 74: ......
Страница 75: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 352: ......
Страница 353: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 431: ...SPECIFICATIONS 5 1 ...
Страница 435: ...PC210LC 11 PC210NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Страница 436: ...PC230NHD 11 SPECIFICATIONS SPECIFICATIONS 5 6 ...
Страница 458: ...PC210 11 2 Piece Boom PC210LC 11 2 Piece Boom PC210NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 22 ...
Страница 459: ...PC230NHD 11 2 Piece Boom ATTACHMENTS AND OPTIONS 2 PIECE BOOM 6 23 ...
Страница 470: ... Not including tail swing SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 34 ...
Страница 505: ...REPLACEMENT PARTS 7 1 ...
Страница 521: ......