“SCR Information” screen message (5): “4 Engine power is
under heavy deration.”
Due to the further deration of engine power, capability the
machine will be limited further.
If the restoration of the KDPF system abnormality is not
performed, engine performance will kept be derated.
Engine power can be restored temporarily from power derate. This engine power restoration works only
when the Inducement status is “Severe Inducement” and Engine power can be restored temporarily from
power derate. This engine power restoration works only when the Inducement status is “Severe Induce-
ment” and relieves back temporarily to the power deration of “Low level Inducement”. The operator can re-
store engine power through the machine monitor. For the engine power restoration procedure, refer to the
section of “Temporary Restoration from Inducement” in this manual. If Inducement advances to “Severe In-
ducement” and it becomes necessary to restore engine power, use the engine power restoration function to
move the machine to a safe place and contact your Komatsu distributor.
Temporary Restoration from Inducement
Temporary Restoration from Inducement is the one of the Inducement strategies allowed to be included in Urea
SCR systems.
In case the Urea SCR system advances to “Severe Inducement”, engine power is derated heavily. This may
cause difficulties of moving the machine to a safe place for adding DEF or troubleshooting and correcting abnor-
malities of the Urea SCR system. For temporary remedies from these difficulties the operator can restore engine
power for a short time to the deration of “Low level Inducement” through the machine monitor. Note that “Tempo-
rary Restoration from Inducement” does not regain full engine power.
“Temporary Restoration from Inducement” can be activated only when the Urea SCR system is in “Severe In-
ducement”. The maximum duration is limited to 30 minutes in each restoration operation, and only 3 operations
are allowed unless all the abnormalities of the Urea SCR system are corrected.
If the system advances to “Severe Inducement”, utilize “Temporary Restoration from Inducement” immediately.
Procedure to activate “Temporary Restoration from Inducement”.
1.
Press F6 to display the “SCR Information” screen when
the Standard screen is on, only when the Urea SCR sys-
tem is in “Severe Inducement”.
2.
Press F6 to display the menu windows popping up in the
bottom half of the “SCR Information”.
The menu windows popping up in the bottom half of the
“SCR Information” screen alternate every 15 seconds as
shown in the graphics A and B.
OPERATION
EXPLANATION OF COMPONENTS
3-135
Содержание PC210-11
Страница 2: ......
Страница 24: ......
Страница 74: ......
Страница 75: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 352: ......
Страница 353: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 431: ...SPECIFICATIONS 5 1 ...
Страница 435: ...PC210LC 11 PC210NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Страница 436: ...PC230NHD 11 SPECIFICATIONS SPECIFICATIONS 5 6 ...
Страница 458: ...PC210 11 2 Piece Boom PC210LC 11 2 Piece Boom PC210NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 22 ...
Страница 459: ...PC230NHD 11 2 Piece Boom ATTACHMENTS AND OPTIONS 2 PIECE BOOM 6 23 ...
Страница 470: ... Not including tail swing SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 34 ...
Страница 505: ...REPLACEMENT PARTS 7 1 ...
Страница 521: ......