REMARK
• The progress of the manual stationary regeneration
performed when soot is accumulated can be checked
by the number of lighting lamps of soot accumulation
level (4). The manual stationary regeneration starts at
soot accumulation level “4” or higher and finishes
when all the level lamps go out.
• The time required for the manual stationary regenera-
tion depends on the soot deposition level or the ambi-
ent temperature when it is started. If the regeneration
starts at soot accumulation level “6” or higher, it may
take approximately 2 hours to finish.
• The manual stationary regeneration for protection of
the system may start even when the soot accumula-
tion level is “0” to “3”. In this case, the soot accumula-
tion level may not decrease, but this is not trouble.
The progress is not displayed on the monitor during
this regeneration. It is completed in approximately 10
minutes.
• If the lock lever or fuel control dial is operated during
the manual stationary regeneration, the regeneration
is stopped automatically. Return the lock lever to
LOCK position (L) and return the fuel control dial to
Low idle (MIN) position, then repeat the procedure
from step 6.
• If the machine needs to be moved during the manual
stationary regeneration, stop the regeneration tempo-
rarily and move the machine, referring to the after-
treatment devices regeneration disable and cancel
procedures described below.
When restarting the manual stationary regeneration,
secure the safety of the machine and around it, then
cancel the regeneration disable.
8.
After the manual stationary regeneration is completed, the screen automatically returns to the standard
screen.
PROCEDURE FOR AFTERTREATMENT DEVICES REGENERATION DISABLE
SETTING
If there is combustible material around the machine and the active regeneration that increases the exhaust tem-
perature must not be performed, the automatic active aftertreatment regeneration can be disabled. Also, the re-
generation in progress can be stopped.
NOTICE
Even if the regeneration is disabled, KDPF soot accumula-
tion caution lamp (1) lights up if soot is accumulated and
the manual stationary regeneration is required. If KDPF
soot accumulation caution lamp lights up, move the ma-
chine to a safe place and perform manual stationary regen-
eration.
If the operation is continued without performing the man-
ual stationary regeneration, it may cause the failure of
KDPF or the engine.
OPERATION
EXPLANATION OF COMPONENTS
3-119
Содержание PC210-11
Страница 2: ......
Страница 24: ......
Страница 74: ......
Страница 75: ...OPERATION Please read and make sure that you understand the SAFETY section before reading this section 3 1 ...
Страница 352: ......
Страница 353: ...MAINTENANCE Please read and make sure that you understand the SAFETY section before reading this section 4 1 ...
Страница 431: ...SPECIFICATIONS 5 1 ...
Страница 435: ...PC210LC 11 PC210NLC 11 SPECIFICATIONS SPECIFICATIONS 5 5 ...
Страница 436: ...PC230NHD 11 SPECIFICATIONS SPECIFICATIONS 5 6 ...
Страница 458: ...PC210 11 2 Piece Boom PC210LC 11 2 Piece Boom PC210NLC 11 2 Piece Boom 2 PIECE BOOM ATTACHMENTS AND OPTIONS 6 22 ...
Страница 459: ...PC230NHD 11 2 Piece Boom ATTACHMENTS AND OPTIONS 2 PIECE BOOM 6 23 ...
Страница 470: ... Not including tail swing SUPER LONG FRONT BOOM AND ARM ATTACHMENTS AND OPTIONS 6 34 ...
Страница 505: ...REPLACEMENT PARTS 7 1 ...
Страница 521: ......