4-6 Using Terminals and Connectors
TOS9200/9201
• If U FAIL and L FAIL are turned on simultaneously, CONTACT FAIL is meant.
• It is impossible to directly control the input signal using a logic IC such as HC.
■
Internal conf
iguration
The same common line is used for the input signal circuit and the output signal cir
-
cuit.
The input signal circuit is pulled up to +12
V
.
Therefore, opening the input terminal
is equi
v
alent to inputting a high-le
v
el signal.
Fig.4-4
Inter
nal con
fi
gur
ation of the SIGNAL I/O b
loc
k
4.2.2
Example
■
Input signal
Contr
ol at a make-contact
Using the mak
e-contact of a relay or switch, set the input
le
v
el to LO
W
.
Contr
ol using a logic elements
Instead of the switch described abo
v
e, use a logic element
such as a transistor
.
F
or the transistor’
s collector current ic, allo
w at least 5 mA.
NOTE
•
•
•
•
•
•
Output
signal
controller
Input
signal
controller
COM
Output signal 1
Output signal 2
Input signal 1
Input signal 2
+15 V
+15 V
COM
S1
COM
ic
Содержание TOS9200
Страница 22: ...P 10 Preface TOS9200 9201...
Страница 116: ...3 78 Basic Operations TOS9200 9201...
Страница 130: ...4 14 Using Terminals and Connectors TOS9200 9201...
Страница 148: ...7 4 Maintenance TOS9200 9201...
Страница 162: ...8 14 Specifications TOS9200 9201...
Страница 170: ...I 4 Index TOS9200 9201...
Страница 171: ......