KHA1000
2-9
2
In
sta
lla
tio
n
a
n
d
P
re
p
ara
tio
n
fo
r U
se
2.4
Connecting the Rear-side Terminals
•
To prevent an electric shock, be sure to remove the power cord from
the outlet or turn off the POWER switch.
The L and N polarities of the LOAD and SOURCE terminals conform to IEC
standard measurement category CAT I or CAT II. This category depends on the
input voltage (Table 2-3).
Table 2-3
Measurement categories
2.4.1
Connecting EUT (LOAD Terminal)
Connect the equipment under test to the LOAD terminals. Match the polarities (L,
N, and G) of the terminals and equipment under test to each other. (G is a protective
grounding or grounding terminal.)
When the equipment under test has a power cord with a plug, connect it to the LOAD
terminals using a relay outlet. Match the polarities (L, N, and G) of the terminals and
relay outlet to each other. (G is a protective grounding or grounding terminal.)
The customer is required to obtain the relay outlet according to the measurement
environment.
Fig.2-5
Connecting the input terminals
WARNING
Input voltage
Measurement category
250 Vrms(exclusive) to
300 Vrms
CAT I: Measures circuits that are not directly connected to
commercial power.
250 Vrms or less
CAT II: Measures the primary-side circuits of devices (such
as home electric appliances and portable tools) that are
directly connected to low-voltage fixtures such as outlets.
INPUT
OUTPUT
L
N
G
EUT
Relay outlet
G N
L
G
N
L
G N L
G N L
Power cord with plug
Voltage sensing terminal
External signal
input terminal
AC power supply
AC power supply
LOAD terminal
SOURCE terminal
Содержание KHA1000
Страница 1: ...Part No Z1 003 482 I0043901 Oct 2021 Operation Manual Harmonic Flicker Analyzer KHA1000 ...
Страница 8: ...vi KHA1000 ...
Страница 20: ...xviii KHA1000 Rear panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Страница 22: ...xx KHA1000 ...
Страница 23: ...Overview This chapter provides an overview of the product and explains its features 1 ...
Страница 30: ...1 8 KHA1000 ...
Страница 68: ...3 20 KHA1000 ...
Страница 69: ...Basic Operation This chapter explains basic operation methods 4 ...
Страница 156: ...5 54 KHA1000 ...
Страница 183: ...Other Measurements This chapter explains measurements for other than harmonic current and voltage fluctuation tests 7 ...
Страница 193: ...Remote Control This chapter explains how to connect the remote interface and how to control it using SCPI commands 8 ...
Страница 260: ...9 6 KHA1000 ...
Страница 261: ...Specifications This chapter explains the specifications of this product 10 ...
Страница 272: ...I 4 KHA1000 ...
Страница 273: ......