5-30
KHA1000
View Setting
Sub Menu
A different sub-menu is displayed for each view type selected. The sub-menus of
the harmonics list and the current and harmonic trends are given below.
Harmonic list
•
Average: Average value from the beginning of the test (A)
•
Max:
Maximum value from the beginning of the test (A)
Page 5-34
Explanation of display items
F1
Item
Average
Max
Select the current view of each harmonic order.
F2
Scroll
Used to view a hidden part. Turn the small knob to
vertically scroll over the display. This is used when the
display is divided into two or four screens. In the
1-screen view, it is displayed in a pale color.
See
Display item
Explanation
No.
Harmonic order
Meas(A)
Harmonic current (A)
•
Measured values that exceed 100 % of the limit value are displayed in red.
•
Measured values that exceed the margin setting value to 100 % of the limit
value are displayed in yellow.
Ave(A)
Average value from test start (A)
•
Average value from the beginning of the test. It has no color change.
• “.......” is displayed in the test conditions setting state (real-time
measurement).
Pk(A)
Maximum value from test start (A)
•
Maximum value from the beginning of the test. It has no color change.
• “.......” is displayed in the test conditions setting state (real-time
measurement).
Lim(A)
Limit value (A)
In the following case, a limit value may be indicated in “.......”
•
There is no limit value
•
A calculated limit value is less than 0.0001 A (0.001 A in the range of 10 A
or more)
Содержание KHA1000
Страница 1: ...Part No Z1 003 482 I0043901 Oct 2021 Operation Manual Harmonic Flicker Analyzer KHA1000 ...
Страница 8: ...vi KHA1000 ...
Страница 20: ...xviii KHA1000 Rear panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Страница 22: ...xx KHA1000 ...
Страница 23: ...Overview This chapter provides an overview of the product and explains its features 1 ...
Страница 30: ...1 8 KHA1000 ...
Страница 68: ...3 20 KHA1000 ...
Страница 69: ...Basic Operation This chapter explains basic operation methods 4 ...
Страница 156: ...5 54 KHA1000 ...
Страница 183: ...Other Measurements This chapter explains measurements for other than harmonic current and voltage fluctuation tests 7 ...
Страница 193: ...Remote Control This chapter explains how to connect the remote interface and how to control it using SCPI commands 8 ...
Страница 260: ...9 6 KHA1000 ...
Страница 261: ...Specifications This chapter explains the specifications of this product 10 ...
Страница 272: ...I 4 KHA1000 ...
Страница 273: ......