KHA1000
5-49
5
H
arm
o
n
ic
C
u
rr
en
t T
es
t
Fig.5-16 Example of report printout
(JIS C61000-3-2(2003) Class A abstract)
Fig.5-17 Example of report printout
(IEC 61000-3-2:Ed3.0 abstract)
Operating mode
Type of test
JIS C61000-3-2(2003)
Date of test
2010/10/18 18:48:37
Climatic condition
Equipment
Class A
Memo
Power analyzer
KHA1000,Ver1.00
Supply Source
Reference Impedance
Test Data of Current Harmonics
FINAL TEST RESULT
Voltage
Current
Apparent Power
THC
POHC/LIMIT
Frequency
Fundamental current
Measuring period
Margin
HarmOrder
Limit1(A rms)
Limit2(A rms)
100%Over(%)
Max(A rms)
Judge
50%Over(%)
2
2.484
3.726
28.9
0.0
2.412
Warning
3
5.290
7.935
0.0
0.0
0.160
Pass
4
0.988
1.482
27.6
0.0
0.532
Warning
5
2.622
3.933
0.0
0.0
0.212
Pass
6
0.690
1.035
0.0
0.0
0.180
Pass
7
1.770
2.655
0.0
0.0
0.116
Pass
PASS *2
102.48 V
11.192 A
1084.8 VA
2.484 A
0.052 A/ 0.341 A*3
50 Hz
11.192 A
150 s
50 %
*2 The values for the final test result are more than Margin value and less than or equal to Limit value.
*3 The POHC which can be calculated from the applicable limits.
5
THD
300.00%
L
L
L
4
6
7
8
9
10
11
2
*
S
SS
AS
PA
2
3
Company
Test Engineer
Model name
Type
Serial No.
Operating mode
Type of test
EN 61000-3-2(2006)
Date of test
2010/10/21 9:47:09
Climatic condition
Classification
Class A
Memo
Power analyzer
KHA1000,Ver1.45
Supply Source
Reference Impedance Bypass
Test Data of Current Harmonics
FINAL TEST RESULT
PASS
Voltage
230.46V
Current
6.338A
Power
457.17W
Apparent Power
1460.6VA
THC
6.018A
POHC/LIMIT
0.472A/ -----A *4
Nominal
230V/ 50Hz
Fundamental current
1.984A
Measuring period
60s
Margin
100%
HARMONICS CURRENT TEST REPORT
HarmOrder
Limit1(A rms)
Limit2(A rms)
Ave(A rms)
EN 61000-4-7(2002)
*IEC 61000-3-2:Ed3.0(2005)
*IEC 61000-4-7:Ed2.0(2002)
Type of equipment behaviour:Quasi-Stationary
Max(A rms)
LimitOver(s)
Judge
2
1.0800
2.1600
0.9294
2.141
5.6
Pass
3
2.3000
4.6000
1.9790
4.559
5.6
Pass
4
0.4300
0.8600
0.3693
0.850
5.6
Pass
5
1.1400
2.2800
0.9788
2.255
5.6
Pass
39
0.0577
0.1154
0.0455
0.104
5.2
Pass
40
0.0460
0.0920
0.0362
0.083
5.0
Pass
*4 When the Edition 3.0 is applied, 200% of the limit 1 value is applied to each Limit 2 value.
THD
300.00%
1
2
3
5
0
5.
12
Содержание KHA1000
Страница 1: ...Part No Z1 003 482 I0043901 Oct 2021 Operation Manual Harmonic Flicker Analyzer KHA1000 ...
Страница 8: ...vi KHA1000 ...
Страница 20: ...xviii KHA1000 Rear panel 1 2 3 4 5 6 7 8 9 10 11 12 13 14 ...
Страница 22: ...xx KHA1000 ...
Страница 23: ...Overview This chapter provides an overview of the product and explains its features 1 ...
Страница 30: ...1 8 KHA1000 ...
Страница 68: ...3 20 KHA1000 ...
Страница 69: ...Basic Operation This chapter explains basic operation methods 4 ...
Страница 156: ...5 54 KHA1000 ...
Страница 183: ...Other Measurements This chapter explains measurements for other than harmonic current and voltage fluctuation tests 7 ...
Страница 193: ...Remote Control This chapter explains how to connect the remote interface and how to control it using SCPI commands 8 ...
Страница 260: ...9 6 KHA1000 ...
Страница 261: ...Specifications This chapter explains the specifications of this product 10 ...
Страница 272: ...I 4 KHA1000 ...
Страница 273: ......