Keysight N5990A MIPI M-PHY Receiver Test User Guide
255
PWM Tests
7
Parameter Name
Parameter Description
Result
"Pass"/"Fail" - If the value is "Fail", the DUT skew tolerance is below the spec limit.
Max Passed Skew
It is the maximum skew value, where the DUT shows no errors.
Min Failed Skew
It is the minimum skew value, where the DUT does not work.
Min Spec Skew
It is the minimum skew value where the DUT must work according to the specification.
Tested Amplitude
It is the amplitude value that is tested.
Tested Offset
It is the offset value that is tested.