Keysight N5990A MIPI M-PHY Receiver Test User Guide
245
PWM Tests
7
Procedure
The data generator sends Burst-mode CJTPAT signaling with nominal
amplitude settings while the DUT is configured for Terminated-mode.
Then, the T
TERM-ON-PWM-RX
(PWM-RX Differential Termination Enable
Time) is measured using a real-time oscilloscope. Among all measured
T
TERM-ON-PWM-RX
values, the maximum and minimum T
TERM-ON-PWM-RX
values are considered as the final results.
The test will pass if the maximum T
TERM-ON-PWM-RX
value is less than the
PREPARE time defined by the DUT´s LS_PREPARE_Length_Capability
attribute (see
This test is performed at each selected lane and PWM gear and it is tested
at the minimum and maximum data rate value for all gears.
Table 42
PWM-Prepare Length Values
Connection Diagram
Refer to the connection diagrams shown in the Connection Diagram
section of the Test 2.1.4-HS-RX Differential Termination Enable Time test
Parameters
The parameters used in
Expert Mode
for this test, are as follows:
• CDR Loop Bandwidth (if CDR is selected in the Special Parameter
dialog, see
)
• CDR Peaking (if CDR is selected in the Special Parameter dialog, see
• CDR Transition Density (if CDR is selected in the Special Parameter
dialog, see
)
• CDR Loop Order (if CDR is selected in the Special Parameter dialog,
see
• Lane Under Test Termination Mode
• Semi Automated Test
• Set Single Ended Amplitude
• Set Offset
Parameter Name
Parameter Value
Parameter Unit
LS_PREPARE_LENGTH
0 to 15
N/a
T
PWM-PREPARE
T
PWM-PREPARE
= Max
(2
(LS_PREPAREGEAR-7)
, 1)
SI
Содержание N5990A
Страница 1: ...User Guide Keysight N5990A MIPI M PHY Receiver Test...
Страница 17: ...Keysight N5990A MIPI M PHY Receiver Test User Guide 1 Introduction Document History 18 Overview 19...
Страница 62: ......
Страница 86: ...86 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Страница 88: ...88 Keysight N5990A MIPI M PHY Receiver Test User Guide 4 Calibrations...
Страница 214: ......
Страница 234: ......
Страница 268: ......
Страница 298: ......