Keysight EXG and MXG X-Series Signal Generators User’s Guide
287
Digital Signal Interface Module (Option 003/004)
Clock Timing
The levels will degrade above the warranted level clock rates, but they may still be usable.
Serial Port Configuration Clock Rates
For a serial port configuration, the lower clock rate limit is determined by the word size (word size
and sample size are synonymous), while the maximum clock rate limit remains constant at 150 MHz
for LVTTL and CMOS logic types, and 400 MHz for an LVDS logic type.
The reverse is true for the sample rate. The lower sample (word) rate value of 1 kHz remains while
the upper limit of the sample rate varies with the word size. For example, a five-bit sample for an
LVTTL or CMOS logic type yields the following values in serial mode:
— Clock rate of 5 kHz through 150 MHz
— Sample rate of 1 kHz through 30 MHz
Refer to
, for the serial clock rates.
1. The IF signal type is not available for a serial port configuration.
Table 10-2
Warranted Parallel Input Level Clock Rates and Maximum Clock Rates
Logic Type
Warranted Level Clock Rates
Maximum Clock Rates (typical)
LVTTL and CMOS
100 MHz
150 MHz
LVDS
200 MHz
200 MHz
Table 10-3
Output Serial Clock Rates
Logic Type
Minimum Rate
Maximum Rate
LVDS
1 x (word size) kHz
400 MHz
LVTTL and CMOS
1 x (word size) kHz
150 MHz
Table 10-4
Input Serial Clock Rates
Logic Type
Data Type
Minimum Rate
Maximum Rate
LVDS
Samples
1 x (word size) kHz
400
Pre-FIR
Samples
1 x (word size) kHz
the smaller of: 50
1
x (word size) MHz
or
400 MHz
1. The maximum sample rate depends on the selected filter when the data rate is Pre-FIR Samples.
for more information.
LVTTL and CMOS
N/A
1 x (word size) kHz
150 MHz
Содержание N5171B EXG
Страница 1: ...User s Guide Keysight X Series Signal Generators N5171B 72B 73B EXG N5181B 82B 83B MXG...
Страница 4: ...iv...
Страница 356: ...340 Keysight EXG and MXG X Series Signal Generators User s Guide BERT Option UN7 Verifying BERT Operation...
Страница 452: ...436 Keysight EXG and MXG X Series Signal Generators User s Guide Troubleshooting Contacting Keysight Technologies...