10
Keysight EXG and MXG X-Series Signal Generators User’s Guide
Signal Generator Overview
Front Panel Display
4. Amplitude Area
This area displays the current output power level setting (If the RF Output is off, this area is greyed
out).
5. Error Message Area
This area displays abbreviated error messages. If multiple messages occur, only the most recent
message remains displayed. See
“Reading Error Messages” on page 68
.
6. Text Area
This area displays signal generator status information, such as the modulation status, and other
information such as sweep lists and file catalogs. This area also enables you to perform functions
such as managing information (entering information, and displaying or deleting files).
DIGMOD
Custom Arb waveform generator is on.
ERR
An error message is placed in the error queue. This annunciator does not turn off until you either view all of the
error messages or clear the error queue (see
“Reading Error Messages” on page
EXTREF
An external frequency reference is applied.
FM
Frequency modulation is on. If you turn phase modulation on, the
Φ
M
annunciator replaces
FM
.
I/Q
I/Q vector modulation is on.
L
The signal generator is in listener mode and is receiving information or commands over the GPIB, USB, or VXI–
11/Sockets (LAN) interface.
M–TONE
Multitone waveform generator is on.
MULT
A frequency multiplier is set (see
“Setting a Frequency Multiplier” on page
).
OFFS
An output offset is set (see
“Setting an Output Offset” on page
PN
Phase noise interference is on.
PULSE
Pulse modulation is on.
R
The signal generator is remotely controlled over the GPIB, USB, or VXI–11/Sockets (LAN) interface. When the
signal generator is in remote mode, the keypad is locked out. To unlock the keypad, press
Local
(see page
).
REF
An output reference is set (see
“Setting an Output Reference” on page
RF OFF
The signal generator’s RF Output is not enabled.
S
The signal generator has generated a service request (SRQ) over the GPIB, USB, or VXI–11/Sockets (LAN)
interface.
SWEEP
The signal generator is currently sweeping in list or step mode.
SWMAN
The signal generator is in manual sweep mode.
T
The signal generator is in talker mode and is transmitting information over the GPIB, USB, or VXI–11/Sockets
(LAN) interface.
T–TONE
Two–Tone waveform generator is on.
UNLEVEL
The signal generator is unable to maintain the correct output level. This is not necessarily an indication of
instrument failure; unleveled conditions can occur during normal operation. Another annunciator,
ALC
OFF
,
appears in the same position when the ALC circuit is disabled (see
ALC
OFF
, above).
UNLOCK
Any of the phase locked loops cannot maintain phase lock. To determine which loop is unlocked, examine the
error messages (see
“Reading Error Messages” on page
WATRG
The current modulation mode is waiting on the Arb trigger.
WINIT
The signal generator is waiting for you to initiate a single sweep.
This annunciator appears when...