Avionics VOR/ILS (Option 302)
Using ILS Localizer Softkeys
Figure 5-9
ILS Localizer Softkeys
When testing an ILS [Instrument Landing System],
the following ILS Localizer parameters can be set:
To set the ILS Localizer mode to produce a full or partial signal
1.
Press Aux Fctn > Avionics > ILS Localizer
2.
Press ILS LOC Mode
(Default selection is OFF.)
- Sets Right Frequency
-Sets DDM Polarity
Left
|
Right
|
In-line
- Sets DDM (Difference
in Depth of Modulation)
- Sets DDM in uA
- Sets DDM in %.
DDM of 1% is
equivalent to 0.001
- Sets the Sum of
Depth of Modulation
- Sets the Phase of the
Right signal relative to
the Left signal
- Turns
off
the Left (90 Hz)
and Right (150 Hz)
ILS Localizer signals
- Turns
on
the Left (90 Hz)
and Right (150 Hz)
ILS Localizer signals
- Turns
off
the Left (90 Hz)
ILS Localizer signal
- Turns
off
the Right (150 Hz)
ILS Localizer signal
- Sets Left Frequency
- Sets a Carrier Frequency by selecting an Index from 1 to 40.
(Default: Index is 1 and corresponds to 108.10 MHz)
ILS Localizer Menu
Parameters
Default State
ILS LOC Mode
OFF
Carrier Freq Index
1
108.10 MHz
Left/Right menu
Left Frequency
90 Hz
Right Frequency
150 Hz
Left/Right Phase
0.00 deg
DDM/SDM menu
Fly Left/Right
None
DDM
0.0000
DDM uA
0.0 uA
DDM%
0.00%
SDM
40.0%
COM/ID menu
a
a. For information on the COM/ID menu,
Содержание N5171B EXG
Страница 1: ...User s Guide Keysight X Series Signal Generators N5171B 72B 73B EXG N5181B 82B 83B MXG...
Страница 4: ...iv...
Страница 356: ...340 Keysight EXG and MXG X Series Signal Generators User s Guide BERT Option UN7 Verifying BERT Operation...
Страница 452: ...436 Keysight EXG and MXG X Series Signal Generators User s Guide Troubleshooting Contacting Keysight Technologies...