Avionics VOR/ILS (Option 302)
Using VOR [VHF Omnidirectional Range] Softkeys
To set the VOR mode that produces a full or partial VOR signal
1.
Press Aux Fctn > Avionics > VOR
2.
Press VOR Mode
(Default selection is OFF.)
3.
Select either: OFF | NORM | VAR | Sub-carrier | Sub-FM
— Selecting
OFF
turns off all VOR modulation. When set to OFF, all VOR mode
parameter settings are turned off, but the selected VOR carrier is still
present on the RF Output connector. To turn off this VOR carrier, set
RF Off/On to Off.
— Selecting
NORM
turns on all VOR signals so that a standard VOR signal is
generated with a default VOR Bearing of zero degrees.
— Selecting
VAR
turns on the main VOR carrier and the 30 Hz variable phase
signal (VAR Freq); suppressed the Sub-carrier.
— Selecting
Sub-carrier
turns on the Sub-carrier without the 30 Hz reference
signal (REF Freq); suppresses the main VOR carrier.
— Selecting
Sub-FM
turns on the Sub-carrier and the 30 Hz reference
signal (REF Freq); suppresses the main VOR carrier.
To set the VOR carrier frequency
1.
Press Aux Fctn > Avionics > VOR
2.
Press Carrier Freq Index
(Default value is 1 and corresponds to 108.00 MHz.)
3.
Select a value from 1 to 160 and press Enter.
The index value that is entered sets the VOR carrier frequency to one of the
standard defined corresponding values and produces a VOR carrier.
VOR carrier frequencies range from 108.00 to 117.95 MHz and can be set by
selecting index values from 1 to 160.
ILS Localizer frequencies range from 108.10 to 111.95 MHz, which overlaps the
VOR carrier frequency range, and can be set by selecting index values from 1
to 40. (For information, see:
“To set the ILS Localizer carrier frequency” on
.)
Because VOR carrier frequencies and ILS Localizer carrier frequencies have a
frequency range that overlaps, only frequencies where the 100 kHz digit is even
(tenths of a megacycle count is even) are used as VOR carrier frequencies.
The default VOR carrier frequency Index is 1 and corresponds to 108.00 MHz.
VOR Carrier Frequencies (MHz) Carrier Freq Index = 1 to 160
1 to 32
33 to 64
65 to 96
97 to 128
129 to 160
Содержание N5171B EXG
Страница 1: ...User s Guide Keysight X Series Signal Generators N5171B 72B 73B EXG N5181B 82B 83B MXG...
Страница 4: ...iv...
Страница 356: ...340 Keysight EXG and MXG X Series Signal Generators User s Guide BERT Option UN7 Verifying BERT Operation...
Страница 452: ...436 Keysight EXG and MXG X Series Signal Generators User s Guide Troubleshooting Contacting Keysight Technologies...