BOP HIPWR 111315
3-23
If current mode is needed, Kepco can modify the unit to establish the voltage limit feedback loop
to use the Sense terminals, rather than the Monitor terminals. The modified unit behaves similar
to that described for voltage mode except that voltage accuracy is 12-bit/ 0.3%, versus 14-bit/
0.1% for voltage mode. Contact Kepco Sales for further details.
3.3.7
CHANGING THE DEFAULT POWER UP SETTINGS
When the BOP is shipped, the following default settings are programmed to be in effect each
time the unit is turned on, however these defaults may be changed as indicated below;
•
Mode: Voltage (may be voltage or current, see PARs. 3.3.2 and 3.4.2. Table 3-7 illus-
trates the relationship between Mode, Main Channel, Protection Type and Levels set-
tings.
•
Main Channel: Internal (may be Internal, External, or External Reference Level, PARs.
and 3.4.3).
•
Protection type: Internal (may be Internal, External, Lesser Limit) (see PARs. and 3.4.4)
•
Levels, Voltage and Current: maximum (see PAR. 3.4.4) Represents the power-up val-
ues for protection limit channels (bipolar limits), voltage for current mode and current for
voltage mode. Table 3-7 illustrates the relationship between Mode, Main Channel, Pro-
tection Type and Levels settings.
•
Output: on (may be on or off) (see PAR. 3.3.5)
To change the default settings refer to the applicable paragraph(s) specified above as needed,
then from the power-up screen press
%
. Highlight Power-up Settings and press
!
. (If a Pass-
word is required, see PAR. 3.2.4.3 for instructions.) Highlight the parameter and press
!
to
modify. Use
Y
,
U
or the
ADJUST
control to highlight a selection, then press
$
to save. To
change a value use the number keys to enter new setting, then
$
to save. When all power-up
settings have been configured, press
$
to save for power up or
%
to exit and abort the
change.
To change the power-up default settings to use different positive and negative limits, first set the
bipolar levels as described above. Then refer to PAR. 3.3.3.1 and set the independent limits as
desired. When complete, press
$
to save for power-up.
To restore the factory default power-up settings listed above, from the power-up screen press
%
. Highlight Power-up Settings and press
!
. Then press
@
to restore the defaults. Then
press
$
to save for power up or
%
to exit and abort the change.
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......