2-24
BOP HIPWR 111315
FIGURE 2-10. MASTER POWER UP SCREEN
1. Adjust the limits to reflect the increased power capacity of the multiple unit combination as
follows:
a. From the main screen, press
%
to enter the General Setup Menu.
b. From the General Setup menu, Highlight Max/Min Settings and press
!
. Press
@
to
restore defaults. Verify that the Max/Min settings reflect the multiple unit combination. For
example, for a parallel combination the values for +Current Max, –Current Min and ±Cur-
rent Protect Max/Min now reflect the total current of the parallel combination. Voltage val-
ues and limits reflect a series combination. For 2 X 2 and 3 X 2 combinations both current
and voltage are affected. NOTE: If desired, these limits may be lowered as described for a
standalone unit (see PAR. 3.3.4).
c. Press
$
to save the settings upon power-up, then
%
to exit the General Setup menu and
return to the power-up screen
TABLE 2-13. SLAVE STATUS MESSAGE DEFINITIONS
Slave Status Message
Displayed on Master Power Up Screen
(see Figure 2-10)
MEANING
Ready
Unit is ready for operation.
STANDBY
If unit’s FAULT indicator is off, hardware error has NOT been detected,
output is ready to be turned on
No Answer
Unit is not responding to polls via BITBUS.
Faulted
Unit’s FAULT indicator is on to indicate a hardware error has been
detected.
Not Used
Unit is not part of parallel configuration
Unknown
Waiting for interface communication
Mode Error
Slave does not match voltage/current or parallel/series configuration
expected by master.
VOLTAGE
SOURCE
CPROTECT
VOLTAGE
CURRENT
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......