BOP HIPWR 111315
3-29
either reducing the number of segments, or increasing the frequency of the existing segments
until the point total is acceptable.
TABLE 3-9. SINE, TRIANGLE AND RAMP WAVEFORM FREQUENCY VS. POINTS
Frequency
(See Notes 1, 2, and 3)
Total Points
Frequency
(See Notes 1, 2, and 3)
Total Points
From
To
From
To
0.01Hz
4
2.7Hz
3840
55.5Hz
66.5Hz
160
2.71Hz
3.6Hz
2880
66.6Hz
88.7Hz
120
3.71Hz
5.5Hz
1920
88.8Hz
118.3Hz
90
5.6Hz
8.3Hz
1280
118.4Hz
147.9Hz
72
8.4Hz
11.0Hz
960
148Hz
177.4Hz
60
11.1Hz
14.7Hz
720
177.5Hz
221.8Hz
48
14.8Hz
22.1Hz
480
221.9Hz
295.8Hz
36
22.2Hz
33.2Hz
320
295.81Hz
354.9Hz
30
33.3Hz
44.3Hz
240
355.9Hz
443.7Hz
24 (See Note 2)
44.4Hz
55.4Hz
192
443.8z
532Hz
20 (See Note 3)
NOTES: 1. As the frequency varies within the range, the time interval per point varies proportionately.
2. Sine and Triangle segments can not exceed 443Hz.
3. Ramp segments can not exceed 532Hz.
4. 0.001 for sine and triangle.
TABLE 3-10. SQUARE WAVEFORM FREQUENCY VS. POINTS
Frequency
(See Note 1)
Total Points
Frequency
(See Notes 1)
Total Points
From
To
From
To
0.02Hz
1.8Hz
3840
43.51Hz
58.0Hz
120
1.81Hz
2.7Hz
2880
58.01Hz
72.5Hz
90
2.71Hz
4.0Hz
1920
72.51Hz
87.0Hz
72
4.01
5.4Hz
1280
87.01Hz
108.7Hz
60
5.41
7.2Hz
960
108.71Hz
145.0Hz
48
7.21Hz
10.8Hz
720
145.2.9Hz
174.0Hz
36
10.81
16.3Hz
480
174.1Hz
217.5Hz
30
16.31Hz
21.7Hz
320
217.6Hz
261.0Hz
24
21.71Hz
27.1Hz
240
261.1Hz
435.0Hz
20
27.11Hz
32.6Hz
192
435Hz
652.5Hz
12
55.5Hz
66.5Hz
160
653
1000
10
NOTE: 1. As the frequency varies within the range, the time interval per point varies proportionately.
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......