BOP HIPWR 111315
1-9
FUNCTION GENERATOR CHARACTERISTICS (Continued)
Amplitude Accuracy
Main Channel
and Offset
Voltage
0.03% EO
NOM
Current
0.1% IO
NOM
Protection Limit.
Channel.
Current
0.5% IO
NOM
Voltage
0.3% EO
NOM
Distortion (THD-F, Total Harmonic Distortion
relative to the fundamental component)
5% max.
Sine
13% max.
Triangle
70% max.
±Ramp
47% max.
Square
Start/Stop Angle (Phase)
Range
0 to 360°
Sine, Triangle
Programming Resolution
0.01°
Accuracy
Start Angle
1°
Stop Angle
1° @ 0.01Hz, to 16° @ 443 Hz
Frequency dependent
SAVE/RECALL CHARACTERISTICS
(See PAR. 3.3.8)
Number of Locations
99
Parameters Saved or Recalled
All parameters saved for power-up.
Mode of operation
Voltage, Current or External
For External the operating mode is deter-
mined by signal at I/O Port; no signal selects
voltage mode (see PAR. 3.4.2).
Reference type
Internal, External or
External Reference Level
Main channel
Internal, External or
Lesser Limit
Limit channel
Main Amplitude
(Internal)
0 to EO
NOM
or IO
NOM
(internal or external)
Main Channel:
Voltage (Volts) for Voltage mode,
Current (Amperes) for Current mode
Protection Limit Amplitude
(Internal)
EO
MIN
or IO
MIN
to
1.01 EO
NOM
or IO
NOM
Limit Channel, Positive and Negative
Voltage (Volts) for Current mode,
Current (Amperes) for Voltage mode
Output status
ON or OFF
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......