B-32
BOP-1K 111315
FIGURE B-10. USING STATUS COMMANDS AND QUERIES
B.121 STATus:questionable:ENABle? QUERY
STAT:QUES:ENAB?
Syntax:
Short Form: STAT:QUES:ENAB? Long Form: STATus:QUESionable:ENABle?
Return Value:
<int_value> actual register value
Description:
Reads Questionable Condition Enable Register (see Table B-4).
Power supply returns value of
Questionable Condition Enable Register, indicating which conditions are being monitored. Bit set to 1
= function enabled (active, true); bit reset to 0 = function disabled (inactive, false)
.
Related Com-
mands:
STAT:QUES?. (See example, Figure B-10.)
NOTES: 1. The power supply is assumed to be operating in constant voltage (CV) mode.
2 Examples below are intended only to illustrate command functions. Refer to PAR. 3.5.2 for
programming techniques to optimize performance.
OUTP:ON
Sets output on.
STAT:PRES
Operation Condition and Questionable Condition registers are
reset.
*CLS
Resets Enable Amplifier
STAT:QUES:ENAB 12228
Allows latching of CE and VE bits
STAT:OPER:ENAB 1280
Mask enabled for CC and CV bits.
STAT:OPER:ENAB?
Returns 1280 (256 + 1024) (CC and CV bits set).
INIT:CONT ON
Continuous triggers enabled.
STAT:OPER:COND?
Power supply returns 256 to indicate that power
supply is in constant voltage mode.
FUNC:MODE:CURR
Commands power supply to current mode.
STAT:OPER?
Returns 1024, indicating that since the last reading
of the Operation Event Register the power supply has entered
Constant Current mode.
STAT:OPER?
Returns 0 indicating no changes since previous reading of the
Operation Event register.
STAT:QUES?
Returns 0 (no questionable conditions occurred since previous
reading
--- OVERCURRENT CONDITION OCCURS
SYST:ERR?
Power supply returns 0,“No error” message.
*RST;:VOLT 5;CURR 1;OUTP ON
The BOP is in Voltage mode and delivering 5 Volts
*ESR?
Bop returns a 0 - all functions are normal
FUNC:MODE CURR
BOP is in Current mode
*ESR?;STAT:QUES:COND?
BOP returns 8;4097 - Current error.
*ESR?;STAT:QUES?
BOP returns 0;4096 - no new errors, Current Error
*ESR?;STAT:QUES?
BOP returns 0;0 - no new errors
MEAS:CURR?;VOLT?
BOP returns 1.0E-4;5.00003E0 - Voltage is 5 volts
STAT:QUES:COND?
BOP returns 4097 - error still in effect
Short is applied to the BOP
*ESR?:STAT:QUES:COND?
BOP returns 0;1 - Current mode is selected
MEAS:VOLT?;CURR?
BOP returns.1E-4;1.00003E0 - Current is 1 amperes
FUNC:MODE VOLT;*ESR?
BOP switches mode, returns 3 - settling
*ESR?:;STAT:QUES?
BOP returns 8;8194
Short is removed from the BOP output
STAT:QUES:COND?
BOP returns 2, voltage mode operation OK.
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......