[SOURce:]VOLTage[:LEVel]:LIMit[:BOTH] COMMAND
VOLT:LIM[:BOTH]
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH] <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH] <value>
where <value> is between zero and rated (nominal) output voltage
Description: Establishes the software limit <value> for output voltage, i.e., sets the maximum value of positive or
negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.90
[SOURce:]VOLTage[:LEVel]:LIMit[:BOTH]? QUERY
VOLT:LIM[:BOTH]?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH]?
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:[:BOTH]?
Returns <value>
Description: Identifies the software limit value for both positive and negative output voltage specified by the user.
B.91
[SOURce:]VOLTage[:LEVel]:LIMit:NEGative COMMAND
VOLT:LIM:NEG
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative <value>
where <value> is between zero and rated (nominal) output voltage
Description: Establishes the software limit <value> for negative output voltage, i.e., sets the maximum value of
negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.92
[SOURce:]VOLTage[:LEVel]:LIMit:NEGative? QUERY
VOLT:LIM:NEG?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG? <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative? <value>
Description: Identifies the software limit value for negative output voltage specified by the user.
B.93
[SOURce:]VOLTage[:LEVel]:LIMit:POSitive COMMAND
VOLT:LIM:POS
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:POS <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:POSitive <value>
where <value> is between zero and rated (nominal) output voltage
Description: Establishes the software limit <value> for positive output voltage, i.e., sets the maximum value of pos-
itive output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to save
for power up. See PAR. 3.5.2.2 and Figure 3-16 for special programming considerations.
B.94
[SOURce:]VOLTage[:LEVel]:LIMit:POSitive? QUERY
VOLT:LIM:POS?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:POS? <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:POSitive? <value>
Description: Identifies the software limit value for positive output voltage specified by the user.
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......