2-8
BOP HIPWR 111315
2.4
INSTALLATION
2.4.1
RACK MOUNTING
The unit is shipped with four feet attached to bottom of the unit which must be removed prior to
installation (see Figure 1-2). The BOP is designed to be rack mounted in a standard 19-inch
wide rack using the mounting ears (supplied) attached to the front panel (see Figure 1-2). Allow
a minimum of 7/8 in. (22.2 mm) above and below the unit to permit air intake necessary for
proper cooling of the unit.
CAUTION: The rack must provide support at the rear (within 6
inches of the rear panel). Optional slides can also be used (see PAR. 2.4.2).
2.4.2
SLIDE INSTALLATION
Optional slides are available for rack mounting (see Table 1-4 and Figure 1-2).
2.5
WIRING INSTRUCTIONS
Interconnections between an a-c power source and a power supply, and between the power
supply and its load are as critical as the interface between other types of electronic equipment.
If optimum performance is expected, certain rules for the interconnection of source, power sup-
ply and load must be observed by the user. These rules are described in detail in the following
paragraphs.
CAUTION: When working with active loads, the voltage or current of the active load
must not exceed the maximum voltage or current rating of the BOP. Other-
wise the overvoltage or overcurrent protection will shut down the power sup-
ply.
2.5.1
SAFETY GROUNDING
Local, national and international safety rules dictate the grounding of the metal cover and case
of any instrument connected to the a-c power source, when such grounding is an intrinsic part of
the safety aspect of the instrument. The ground terminal of the source power connector (Figure
2-1) is connected to the chassis and the instructions below suggest wiring methods which com-
ply with these safety requirements; however, in the event that the specific installation for the
power system is different from the recommended wiring, it is the customer's responsibility to
ensure that all applicable electric codes for safety grounding requirements are met. As a pre-
caution, always connect the stud marked
at the rear panel to proper earth ground.
2.5.2
SOURCE POWER CONNECTIONS
Source power is connected to the power supply via three-wire input power using the source
power mating connector supplied (see Table 1-3). See Table 1-2 for source power specifica-
tions. This power supply operates from single phase a-c mains power (or between two phases
of 3-phase a-c mains power) over the specified voltage and frequency ranges (Table 1-2) with-
out any need for range selection. The user must provide aproperly sized and rated mains lead
(line cord) and service with a current rating compatible with the anticipated input current. Line
cords available as accessories are listed in Table 1-4. Kepco recommends #12 AWG (2,0 mm
diameter)
for input line cord.
2.5.3
D-C OUTPUT GROUNDING
Connections between the power supply and the load and sensing connections may, despite all
precautions such as shielding, twisting of wire pairs, etc., be influenced by radiated noise, or
“noise pick-up”. To minimize the effects of this radiated noise the user should consider ground-
ing one side of the power supply/load circuit. The success of d-c grounding requires careful
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......