1-6
BOP HIPWR 111315
FUNCTION GENERATOR CHARACTERISTICS
(See PAR. 3.3.9)
Maximum number of waveforms
Local: 16
Remote: 1
Local: Saved for power-up
Remote: Lost when the unit is turned off, must
be saved on the host computer)
Maximum number of segments or basic wave-
forms per waveform
Local: 10
Remote: 126
Or maximum number of points (whichever
comes first)
•
The time interval for each segment
depends on the type of waveform: period
for ramp and square waveforms, period or
fraction of period for sine and triangular
waveforms and time interval for DC levels
•
Segments that cause the waveform to
exceed the maximum number of points are
not executed. For local operation they are
marked with a triple asterisk on the front
panel. For remote operation an error mes-
sage is generated.
Types of Basic waveforms
Sine (Sinusoidal waveform)
Triangle (Triangular waveform)
Pos. Ramp (Ramp waveform)
Neg. Ramp (Sawtooth waveform)
Square (50% Duty Cycle Pulse)
Level (DC waveform)
Maximum number of points per basic wave-
form
Local: 3933
Count (Number of repetitions)
Range: 1 to 255
For Count = 0 the waveform is exe-
cuted indefinitely until stop com-
mand is sent
•
Local: Factory default: when the count is
complete or if execution is stopped using
%
, the output of the unit is set to OFF
(Standby indicator lit). Output must be
enabled (press STANDBY) to execute the
waveform again. (See Table 3-3, WAVE-
FORM STOP for additional settings.)
•
Remote: When the count is complete or
the waveform is stopped using the
VOLT:MODE FIX command, the output
remains at last output value.
Waveform Name
10 characters maximum
Waveform Parameters
Type: Voltage or Current
Positive Protection Limit:
(Vd-c or Ad-c)
Negative Protection Limit:
(Vd-c or Ad-c)
Count: number
Initial/Repeating
•
Type of waveform, voltage or current, can
be selected only for a new waveform and
consequently applies to all waveform seg-
ments. Changing the type for an existing
waveform is not possible, unless the wave-
form is erased first.
•
The Limit values (positive/negative) and
the count number apply to all waveform
segments and can be edited at the begin-
ning of a new waveform or later when mod-
ifying a waveform (see PAR. 3.3.9.7).
•
All segments except the last may be set to
run once (Initial) or per the Count setting
(Repeating).
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......