BOP HIPWR 111315
3-47
3.5.3.1
GPIB PORT SETUP
The following paragraphs describe the how to configure the GPIB port.
3.5.3.1.1 CHANGING THE GPIB ADDRESS
The default address is 6. To change the GPIB address press
%
from the power-up screen,
then press
!
to enter the Interface menu (see Table 3-16) Highlight GPIB Address and press
!
, then use the number keys to enter the desired address and press
$
to save. Press
$
to
save for power-up or
%
to apply the changes (without saving for power-up) and exit.
TABLE 3-16. INTERFACE SETTINGS MENU
SETTING
CHOICES
(
BOLD
= Factory Default)
FUNCTION
Interface
Data Format
SCPI
CIIL
SCPI (Standard Commands for Programmable Instruments) - see PAR.
3.6. and Appendix B.
CIIL - Provides compatibility with early Kepco power supplies and con-
trollers.
GPIB Address
0 - 30 (
06
)
Assigns address used by external GPIB controller to communicate with
BOP.
*RST set Output
OFF
ON
OFF - Sending *RST causes output to go off (per IEEE 488.2 specifica-
tions) (see PAR. 3.5.3.1.3 for details).
ON - Sending *RST causes output to go on (see PAR. 3.5.3.1.3 for
details).
Device Clear
SCPI
MATE
SCPI - sending Device Clear (DCL) or selected DCL has no effect on
output voltage and current per IEEE specification 488.2.
MATE - When device clear is received, the power supply output is set to
zero volts.
Serial Baud Rate
OFF
9600
19200
Selects RS 232 serial port baud rate.
Xon/xoff
ENABLE
DISABLE
ENABLE - Allows BOP to control when data is received (see PAR.
3.5.6.2.1).
DISABLE - Disables XON/XOFF. If both Serial XON/XOFF and Prompt
functions are disabled, Echo mode is the default (see PAR. 3.5.6.2.2).
Prompt
DISABLE
ENABLE
ENAB+ECHO
ENABLE - Enables Serial Prompt (see PAR. 3.5.6.2.3).
DISABLE - Disables Prompt. If both Serial XON/XOFF and Prompt
functions are disabled, Echo mode is set (see PAR. 3.5.6.2.2).
ENAB+ECHO - Enables Serial Prompt (see PAR. 3.5.6.2.3) and Echo
(see PAR. 3.5.6.2.2) modes. Prompt is returned when the unit is ready
and any received characters are echoed back to the sender.
NOTE: To restore all interface settings defaults, press
%
from the power-up screen, highlight Interface Settings, press
!
, then
press
@
to restore defaults shown above in
BOLD
. Press
$
to save for power-up or
%
to apply the changes
(without saving for power-up) and exit.
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......