BOP HIPWR 111315
3-39
FIGURE 3-13. REMOTE SHUTDOWN USING INTERNAL POWER, STANDALONE UNITS
FIGURE 3-14. REMOTE SHUTDOWN USING INTERNAL POWER, MULTIPLE UNITS,
3.4.1.2
REMOTE STANDBY
A standalone unit or a multiple unit configuration (parallel, series or series-parallel) can be set to
STANDBY status by applying a remote signal to the TRIGGER PORT as shown in Figure 3-15.
For multiple unit configurations this signal must be applied to the master. When the signal is
momentarily active (short or logic 0 for a minimum of 100
S), the output is set to OFF after a
maximum delay of 200 mS and the STANDBY indicator goes on. Depressing the STANDBY key
or sending the OUTP ON command via the remote interface restores the unit to the previous
state and the STANDBY indicator goes off.
FIGURE 3-15. REMOTE STANDBY, STANDALONE OR MULTIPLE UNITS