BOP HIPWR 111315
1-5
PROGRAMMING/DISPLAY CHARACTERISTICS (Continued)
External Protection Port
(see Table 2-4)
External Shutdown
Isolated input for shutdown of the
BOP (latched status)
Pulse width: 100
S min.
Action delay: 100
S max
Restore operation by cycling input power or
pressing
RESET
key.
External Shutdown
Flag
Isolated output indicating
shutdown status)
Action delay: 100
S max
External On-Off
Flag or External
Trigger
Flag: Isolated output indicating
output on (enabled, STANDBY off) or
off (disabled, STANDBY on) status)
Trigger: Isolated trigger output for
external devices.
Flag:
LIST:SET:TRIG enables trigger function.
Flag action delay: 200 mS max
Trigger:
LIST:CLE disables trigger and restores flag.
Trigger output pulse duration:
settable between 0.25 to 34mS
Trigger output action delay: 100
S max.
Trigger output active level: settable to either
“0” or “1.”
Trigger Port (See Table 2-3)
Shutdown (pin 2):
Operation of pin 2 is controlled by OUTP:CONT command (see Par. B.15).
Settings are STANDBY (default), HIGH, LOW, OFF. Either OFF or STANDBY is
required if using OUTP ON and OUTP OFF commands to control the output.
STANDBY (default) External Trigger Shutdown (Isolated
input. Logic 0 or short-circuit causes
the output to go to STANDBY (off,
disabled) (latched status)
Pulse width: 100
S min.
Action delay: 200 mS max
Restore operation by pressing
STANDBY
key.
or sending OUTP ON command via remote
interface.
HIGH Isolated Input for controlling output
status, on or off. High or open (not
connected), output is on (enabled).
When 0 volts or short circuit applied
to the pin, output is off (disabled)
Pulse width: 6 mS min for any guaranteed unit
response.
Action delay: 200 mS max
LOW Isolated Input for controlling output
status, on or off. Logic 0 = output is
on (enabled); Logic 1 or open (not
connected) = output is off (disabled).
Pulse width: 6 mS min for any guaranteed unit
response.
Action delay: 200 mS max
OFF Trigger port disabled. Inputs applied
to pin 2 have no effect.
External Trigger
Input (pin 4)
Isolated input for trigger events
Pulse width: 100
S min.
Action delay: 500
S max
Digital control
local
Panel-mounted keypad
Direct Entry
remote
IEEE 488-2 (GPIB)
SCPI
remote
RS 232
remote
RS 485 (BITBUS)
Used for series and parallel configurations.
Display
front panel
4" backlit LCD displays all functions
remote
All parameters read back on GPIB or RS 232 buses
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION
CONDITION
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......