BOP-1K 111315
B-23
B.78
[SOURce:]LIST:VOLTage? QUERY
LIST:VOLT?
Syntax:
Short Form: LIST:VOLT?
Long Form: LIST:VOLTage?
Return Value: <value1>, <value2>, . . . to <value16>
Description:
Identifies the parameters (main channel) entered for the list.
Starting at location established by
LIST:QUERy, returns comma-separated list of up to 16 values indicating the main channel parameters
entered. i.e., the contents of the main channel locations of Table B-2. Related Commands: LIST:
VOLT, LIST:QUERy. If LIST:CURR has any entries, an error message: -221,”Settings conflict” is
posted in the error queue. (See example, Figure B-5.)
B.79
[SOURce:]LIST:VOLTage:APPLy COMMAND
LIST:VOLT:APPL
Syntax:
Short Form: LIST:VOLT:APPL <type>,<value1>,<value2>[,<value3>]
Long Form: LIST:VOLTage:APPLy <type>,<value1>,<value2>[,<value3>]
Where <type> is {SQUARE | RAMP+ | RAMP- | TRIANGLE | SINE | LEVEL}
<value1> is frequency (or period (duration) for level)
<value2> is p-p amplitude (or amplitude (offset) for level)
<value3> is offset (optional, default is 0, not applicable to level)
Description:
Causes the unit to add a series of points to both the list:volt array and the list:dwell array to
make either a level or a waveform of one of five types.
Refer to table 3-11 for a description of the
waveform types. The waveform type specified is generated at the frequency specified with a peak-to-
peak amplitude centered on zero. If the optional offset value is specified, the center of the generated
series of points is moved off zero. The apply generator takes into account the soft limits for the voltage
channel and insures the generated array does not exceed the unit’s capabilities.
B.80
[SOURce:]LIST:VOLTage:APPLy:SWEep COMMAND
LIST:VOLT:APPL:SWE
Syntax:
Short Form: LIST:VOLT:APPL:SWE <>,
Long Form: LIST:VOLTage:APPLy:SWEep <value1>,<value2>
Where <value1> is start angle. Valid from 0 to 359.99 degrees.
<value2> is stop angle. Valid from 0.01 to 360.00 degrees
Description:
Allows the user to provide a starting angle for either triangle and sine waveforms and an
optional stop angle.
If the stop angle is not supplied, the unit defaults to 360 degrees. This command
should be placed at the beginning of the waveform program to be applicable to all sine and triangle
waveform segments.
B.81
[SOURce:]LIST:VOLTage:APPLy:SWEep? QUERY
LIST:VOLT:APPL:SWE?
Syntax:
Short Form: LIST:VOLT:APPL:SWE? Long Form: LIST:VOLTage:APPLy:SWEep?
Return Value: <value1>, <value2>(0.01 to 360)
Description:
Returns start
<value1>
and stop
<value2>
angle in degrees for either triangle and sine wave-
forms.
B.82
[SOURce:]LIST:VOLTage:POINts? QUERY
LIST:VOLT:POIN?
Syntax:
Short Form: LIST:VOLT:POIN? Long Form: LIST:VOLTage:POINts?
Return Value: <n> where n = number of points used
Description:
Identifies the total number of points in a list and the next location to be filled by LIST:VOLT
command.
The LIST:VOLT pointer is initially at 0 via LIST:CLE. For each data point entered by a
LIST:VOLT command the list pointer is incremented If LIST:VOLT:POIN? returns 5, the LIST:VOLT
pointer is at 5 indicating there are 5 data points comprising the list (locations 0 though 4) and location
5 is the next to be filled. If LIST:CURR has any entries, an error message: -221,”Settings conflict” is
posted in the error queue. Related Commands: LIST:VOLT. (See example, Figure B-5.)
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......