3-30
BOP HIPWR 111315
3.3.9.4
WAVEFORM SPECIFICATIONS
Refer to Table 1-2 for specifications applicable to waveforms created either locally, using the
BOP front panel (Local) or remotely from a host computer, using LIST commands (Remote). Dif-
ferences between local and remote operation are highlighted.
3.3.9.5
VIEWING STORED WAVEFORMS
After observing the precautions of PAR. 3.3.9.1, press
@
from the power-up screen to access
the Saved Waveforms screen (Figure 3-9). Use
Y
or
U
or the encoder to highlight the name of
a previously saved waveform, then press
!
to view the Waveform Settings screen (see Figure
3-10). The lower half of the LCD shows a representation of the programmed waveform. The let-
ters along the vertical axis of the graph at the lower left side indicate whether the waveform is
programmed to operate in voltage or current mode. The message at the upper right indicates
the actual mode of the power supply while the waveform is being executed. The upper half pres-
ents the waveform name, positive and negative protection settings, the repetition count, fol-
lowed by a listing of segments. The type (square, sine, etc.), frequency, p-p amplitude, and
whether the segment is initial (run only the first time) or repeating is indicated by I or R, respec-
tively. To see the offset, start/stop angle, initial/repeat for a segment, use
Y
or
U
or the
encoder to highlight the segment, then press
!
(Initial/Repeat is not available for the last seg-
ment, since the last segment must repeat). Use use
Y
or
U
to highlight the parameter, press
!
, then set the value or highlight the desired setting and press
$
to save for power-up or
%
to abort and exit without changing the parameter.
FIGURE 3-10. WAVEFORM SETTINGS MENU
3.3.9.6
EXECUTING A WAVEFORM
After observing the precautions of PAR. 3.3.9.1, press
@
from the power-up screen to enter
the Saved Waveforms screen (Figure 3-9). Highlight one of the stored waveforms, then press
!
. If the unit is in Standby, press the
STANDBY
key to turn the output on, then press
$
to
execute the waveform.
To stop execution, press
%
. This stops waveform execution. The unit will stop the waveform
and leave the BOP in one of three states. Standby - the output will be off (STANDBY indicator
on). At the current point of the wave form. The BOP output will be at some random point in the
VOLTAGE
SOURCE
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......