3-8
BOP HIPWR 111315
apply only to local operation.
When in remote, only the main password is accessible, acting
as a general password (see PAR B.140)
.
The functions that can be password protected are
Interface settings, Max/Min settings, Load type, Test, Calibration, Power-up Settings, and Key-
pad lockout at power-up (see Figure 3-5 for factory default password settings). In addition, it is
possible to prevent changes made to the display settings from being saved for power up by set-
ting Save Display Chg to Disable.
When the unit is operating in remote mode with Keypad @ local activated, a password is
required before the unit can be returned to local operation. In addition, when a waveform is exe-
cuting in local mode, depressing
%
to stop the waveform requires a password before the
waveform is stopped.
To change any password you must enter the Admin 2 password to access the Password Menu.
The unit is shipped with the Admin 2 password set to “
KEPCO
,” the Main Unit password set to
”
DEFAULT
,” and the Admin 1 password is not assigned. To change the password or to protect
one of the protected menus, proceed as follows:
1. Press
%
from the power-up screen to enter the General Setup menu. Highlight Password
and press
!
.
2. Enter the Admin 2 password (see PAR. 3.2.4.3 for details), then press
!
to verify. The
Password Protection menu (see Figure 3-5) is now displayed.
3. To change a password, highlight the Main Unit, Admin 1 or Admin 2 password and press
!
to modify.
4. Press
CLEAR
to erase the previous password from memory.
5. Enter the new password (see PAR. 3.2.4.3) and press
$
to save. Up to eight characters
are permitted for passwords.
NOTE: Do NOT use space characters for passwords
6. To protect or unprotect a menu highlight the password setting for the menu (Interface, Max-
Min, Load, Test, Power-up, Keyboard @ Local, Keypad@power-up) and press
!
to modify.
Highlight either the desired password (Main Unit, Admin 1 or Admin 2) or Unprotected and
press
$
to save.
NOTE: To restore the password protection defaults shown in Figure 3-5, press
@
; this leaves
the three individual passwords remain unchanged.
7. When complete, press
$
to save for power-up or
%
to apply the changes (without saving
for power-up) and exit.
3.2.4.3
HOW TO ACCESS A PASSWORD PROTECTED MENU
An administrator can independently assign one of three passwords (Main Unit, Admin 1 or
Admin 2) to eight functions. Under General Setup the Series/Parallel submenu is assigned the
Admin 2 password; this cannot be changed.
When trying to modify a protected setting or access a protected menu, the message PASS-
WORD IS REQUIRED appears at the top, and the first character is highlighted. Proceed as fol-
lows:
Содержание BOP-MG 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP SERIES POWER SUPPLY...
Страница 39: ...BOP HIPWR 111315 1 19 1 20 Blank FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 40: ......
Страница 56: ...2 16 BOP HIPWR 111315 FIGURE 2 5 PARALLEL CONFIGURATION LOCAL SENSING TYPICAL...
Страница 57: ...BOP HIPWR 111315 2 17 FIGURE 2 6 PARALLEL CONFIGURATION REMOTE SENSING TYPICAL...
Страница 68: ......