7. Press «Enter».
The display for hours,
00:00 flashes.
8. Use «Up» or «Down» to set the hours.
9. Press the «Right» arrow.
10. The display for minutes, 00:
00 flashes.
11. Use «Up» or «Down» to set the minutes.
12. Press the «Enter» key.
The setting is applied.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
6 Time control
Menu
······························
01
Mon-Fri
06:30AM
on
Switching point 01 is set
02
Mon-Fri
12:00PM
off
Switching point 02 is set
03
Mon-Fri
01:00PM
on
Switching point 03 is set
04
Mon-Thu
05:00PM
off
Switching point 04 is set
05
Fri
03:00PM
off
Switching point 05 is set
13. Press the «Right» arrow.
14. Press «Enter».
The
on/off indicator flashes.
15. Use «Up» or «Down» key to set the action
on.
16. Press the «Enter» key.
The setting is applied.
The
on action is set for the first switching point.
17. Set the other switching points in the same manner.
Result Weekdays, time and the actions
on / off are set for all switching points of the user-defined clock
program.
8.5.1.3 Activating the «Time control» key
1. Use «Up» or «Down» to select the
Key time control line.
2. Press «Enter».
The check box
Key time control will flash.
4 0 0 m b a r
0 8 : 1 5 A M
8 0 ° C
Header
6 Time control
Menu
Key time control
☑
Active line with deactivated check box
Reset
☐
······························
01
Mon-Fri
06:30AM
on
Switching point 01:
02
Mon-Fri
12:00PM
off
Switching point 02
03
Mon-Fri
01:00PM
on
Switching point 03
3. Press the «Up» key.
The check box is activated.
8
Initial Start-up
8.5
Machine start and machine stop
84
Service Manual Controller
SIGMA CONTROL 2 BLOWER ≥ 4.0.X
No.: 901700 14 E
Содержание SIGMA CONTROL 2
Страница 2: ...KKW SSC 2 15 en IBA SIGMA CONTROL BLOWER KKW SSC 2 15 20220810 080650...
Страница 8: ...List of Illustrations vi Service Manual Controller SIGMA CONTROL 2 BLOWER 4 0 X No 901700 14 E...
Страница 12: ...List of Tables x Service Manual Controller SIGMA CONTROL 2 BLOWER 4 0 X No 901700 14 E...